This is a data sheet for Synergy Microwave's triple-balanced mixers. Here's a breakdown of the key information:
1. Product Overview:
️· Type: Triple-Balanced Mixers
️· Key Feature: Very High Dynamic Range
️· Intended Use: Mix signals within a specified frequency range.
2. Electrical Specifications (Tables):
The data sheet uses tables to define performance metrics. Here's how to interpret those:
️· Frequency Range (MHz): Specifies the supported RF (Radio Frequency), LO (Local Oscillator), and IF (Intermediate Frequency) ranges.
️· Conversion Loss (dB): The amount of signal power lost during the mixing process. Lower is better. The data is categorized by frequency bands:
- XMB (Extra Medium Band): A specific frequency range.
- FULL BAND: The complete frequency range the mixer can handle.
- LB (Low Band), MB (Medium Band), UB (Upper Band): Subdivisions of the frequency range, providing more detailed performance data.
️· LO-RF Isolation (dB): A measure of how well the LO signal is prevented from leaking into the RF port. Higher isolation is better.
️· LO-IF Isolation (dB): A measure of how well the LO signal is prevented from leaking into the IF port. Higher isolation is better.
3. Additional Specifications (Notes):
️· LO Power: Recommended LO drive level is +17 dBm.
️· 1dB Compression Point: +14 dBm (Typical)
️· IP3 (Input): +26 dBm (Typical) - A measure of linearity.
️· Conversion Loss Variation: Conversion loss can increase up to 8dB as the IF frequency decreases towards DC.
️· Maximum Input Power: 500 mW average continuous wave (cw).
4. Definitions of Bandwidth Terms:
️· XMB: 2LF to HF/2
️· FULL BAND: LF to HF
️· LB: LF to 10LF
️· MB: 10LF to HF/2
️· UB: HF/2 to HF
5. Pin-Out and Physical Characteristics:
️· Pin Connection Note: Pins must be connected together.
️· GND: Ground externally.
️· Package Types: THROUGH HO, OLE (TO-CAN)
️· Pin Out: (Not fully visible in the provided snippet but it indicates a pin-out table is present)
6. Contact Information:
️· Synergy Microwave's address, phone number, fax, email, and website are provided.
In essence, this document provides the technical specifications for a range of high-performance triple-balanced mixers, allowing engineers to determine if the mixer meets the requirements of their application. The key parameters to consider are the frequency range, conversion loss, isolation, and maximum input power.
This is a data sheet for Synergy Microwave's triple-balanced mixers. Here's a breakdown of the key information:
1. Product Overview:
️· Type: Triple-Balanced Mixers
️· Key Feature: Very High Dynamic Range
️· Intended Use: Mix signals within a specified frequency range.
2. Electrical Specifications (Tables):
The data sheet uses tables to define performance metrics. Here's how to interpret those:
️· Frequency Range (MHz): Specifies the supported RF (Radio Frequency), LO (Local Oscillator), and IF (Intermediate Frequency) ranges.
️· Conversion Loss (dB): The amount of signal power lost during the mixing process. Lower is better. The data is categorized by frequency bands:
- XMB (Extra Medium Band): A specific frequency range.
- FULL BAND: The complete frequency range the mixer can handle.
- LB (Low Band), MB (Medium Band), UB (Upper Band): Subdivisions of the frequency range, providing more detailed performance data.
️· LO-RF Isolation (dB): A measure of how well the LO signal is prevented from leaking into the RF port. Higher isolation is better.
️· LO-IF Isolation (dB): A measure of how well the LO signal is prevented from leaking into the IF port. Higher isolation is better.
3. Additional Specifications (Notes):
️· LO Power: Recommended LO drive level is +17 dBm.
️· 1dB Compression Point: +14 dBm (Typical)
️· IP3 (Input): +26 dBm (Typical) - A measure of linearity.
️· Conversion Loss Variation: Conversion loss can increase up to 8dB as the IF frequency decreases towards DC.
️· Maximum Input Power: 500 mW average continuous wave (cw).
4. Definitions of Bandwidth Terms:
️· XMB: 2LF to HF/2
️· FULL BAND: LF to HF
️· LB: LF to 10LF
️· MB: 10LF to HF/2
️· UB: HF/2 to HF
5. Pin-Out and Physical Characteristics:
️· Pin Connection Note: Pins must be connected together.
️· GND: Ground externally.
️· Package Types: THROUGH HO, OLE (TO-CAN)
️· Pin Out: (Not fully visible in the provided snippet but it indicates a pin-out table is present)
6. Contact Information:
️· Synergy Microwave's address, phone number, fax, email, and website are provided.
In essence, this document provides the technical specifications for a range of high-performance triple-balanced mixers, allowing engineers to determine if the mixer meets the requirements of their application. The key parameters to consider are the frequency range, conversion loss, isolation, and maximum input power.
| Part No. | CMP-610 |
| Manufacturer | SYNERGY |
| Size | 45 Kbytes |
| Pages | 2 pages |
| Description | MIXERS TRIPLE-BALANCED |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |