192 / 204 page ![]() ® ® 190 www.lemo.com Test voltage (Ue) : (measured according to the IEC 60512-2 test 4a standard) It corresponds to 75% of the mean breakdown voltage. Test voltage is applied at 500 V/s and the test duration is 1 minute. This test has been carried out with a mated plug and socket, with power supply only on the plug end. The operating voltage value definition is at the entire responsibility of the customer who defines this value according to the safety factors that they apply to their equipment and system. Caution: For a number of applications, safety requirements for electrical appliances are more severe with regard to operating voltage. In such cases operating voltage is defined according to creepage distance and air clearance) between live parts. Please consult us for the choice of a connector by indi- cating the safety standard to be met by the product. Voltage values are given in the table on insulator types for each series. They correspond with values measured at sea level. They are adapted to all applications up to an altitude of 2000 m. In case a device is used at a higher altitude, air clearance between live parts has to be multiplied by the following coefficients. It means also that test voltage has to be divided by this coefficient. Print contacts straight elbow Print contacts are available in straight or elbow versions for certain connector types, mostly for straight and elbow socket models. Connection is made on flexible or rigid printed circuits by soldering. Straight print contacts are gold-plated which guarantees optimum soldering, even after long-term storage. However for wave soldering, we recommend removal the gold-plat- ing from the contact end on the printed circuit side before soldering according to the assembly procedures. Print elbow contacts include a tinned lead free brass wire crimped into a crimp contact. (measured according to IEC 60512-3 test 5a) The specified rated current can be applied simultaneously to all the contacts. It corresponds with an average temperature rise of 40°C of the connector. The current values are indicated in the table of insulator types in each series. For use at higher temperatures acceptable rated current will be lower. It tends towards zero as the material is used at the maximum operating temperature accepted for the insulator. In most case the current depend on the conductor dimension (see table on page 196) or on the printed circuit dimension. Caution: In general, connectors should not be unmated while live. Test voltage 0 50 25% 50% 75% 100% 100 150 200 250 T (°C) Rated current For connectors with PEEK insulator, maximum admissible current will follow the curve below depending on the oper- ating temperature T. Rated current (A) coefficient 1.00 1.14 1.29 1.48 altitude (m) 2000 3000 4000 5000 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |