Electronic Components Datasheet Search |
|
ADIS16488A Datasheet(PDF) 3 Page - Analog Devices |
|
|
ADIS16488A Datasheet(HTML) 3 Page - Analog Devices |
3 / 35 page Product Overview Online Documentation Design Resources Discussion Sample & Buy Data Sheet ADIS16488A Rev. C | Page 3 of 35 SPECIFICATIONS TC = 25°C, VDD = 3.3 V, angular rate = 0°/sec, dynamicrange = ±450°/sec± 1 g, 300 mbar to 1100 mbar, unless otherwisenoted. Table 1. Parameter Test Conditions/Comments Min Typ Max Unit GYROSCOPES Dynamic Range ±450 ±480 °/sec Sensitivity x_GYRO_OUT and x_GYRO_LOW (32-bit) 3.052 × 10−7 °/sec/LSB Repeatability1 −40°C ≤ TC ≤ +85°C ±1 % Sensitivity Temperature Coefficient −40°C ≤ TC ≤ +85°C, 1 σ ±35 ppm/°C Misalignment Axis to axis ±0.05 Degrees Axis to frame (package) ±1.0 Degrees Nonlinearity Best fit straight line, FS = 450°/sec 0.01 % of FS Bias Repeatability1, 2 −40°C ≤ TC ≤ +85°C, 1 σ ±0.2 °/sec In-Run Bias Stability 1 σ 5.1 °/hr Angular Random Walk 1 σ 0.26 °/√hr Bias Temperature Coefficient −40°C ≤ TC ≤ +85°C, 1 σ ±0.0025 °/sec/°C Linear Acceleration Effect on Bias Any axis, 1 σ (CONFIG[7] = 1) 0.009 °/sec/g Output Noise No filtering 0.135 °/sec rms Rate Noise Density f = 10 Hz to 40 Hz, no filtering 0.0059 °/sec/√Hz rms 3 dB Bandwidth 330 Hz Sensor Resonant Frequency 18 kHz ACCELEROMETERS Each axis Dynamic Range ±18 g Sensitivity x_ACCL_OUT and x_ACCL_LOW (32-bit) 1.221 × 10−8 g/LSB Repeatability1 −40°C ≤ TC ≤ +85°C ±0.5 % Sensitivity Temperature Coefficient −40°C ≤ TC ≤ +85°C, 1 σ ±25 ppm/°C Misalignment Axis to axis ±0.035 Degrees Axis to frame (package) ±1.0 Degrees Nonlinearity Best fit straight line, ±10 g 0.1 % of FS Best fit straight line, ±18 g 0.5 % of FS Bias Repeatability1,2 −40°C ≤ TC ≤ +85°C, 1 σ ±16 mg In-Run Bias Stability 1 σ 0.07 mg Velocity Random Walk 1 σ 0.029 m/sec/√hr Bias Temperature Coefficient −40°C ≤ TC ≤ +85°C ±0.1 mg/°C Output Noise No filtering 1.29 mg rms Noise Density f = 10 Hz to 40 Hz, no filtering 0.063 mg/√Hz rms 3 dB Bandwidth 330 Hz Sensor Resonant Frequency 5.5 kHz MAGNETOMETER Dynamic Range ±2.5 gauss Sensitivity 0.1 mgauss/LSB Initial Sensitivity Tolerance ±2 % Sensitivity Temperature Coefficient ADIS16488BMLZ, −40°C ≤ TC ≤ +85°C, 1 σ 275 ppm/°C ADIS16488CMLZ, −40°C ≤ TC ≤ +85°C, 1 σ 60 ppm/°C Misalignment Axis to axis 0.35 Degrees Axis to frame (package) 1.0 Degrees Nonlinearity Best fit straight line 0.5 % of FS Initial Bias Error 0 gauss stimulus ±15 mgauss Bias Temperature Coefficient ADIS16488BMLZ, −40°C ≤ TC ≤ +85°C, 1 σ 0.3 mgauss/°C ADIS16488CMLZ, −40°C ≤ TC ≤ +85°C, 1 σ 0.03 mgauss/°C Output Noise No filtering 0.22 mgauss rms Noise Density f = 2 Hz to 5 Hz, no filtering 0.042 mgauss/√Hz 3 dB Bandwidth 330 Hz BAROMETER Pressure Range 300 1100 mbar Extended 10 1200 mbar |
Similar Part No. - ADIS16488A |
|
Similar Description - ADIS16488A |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.NET |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |