107 / 144 page ![]() ST72774/ST727754/ST72734 107/144 DDC INTERFACE (Cont’d) 4.8.5.2 DDC/CI - Factory Alignment Interface 4.8.5.2.1 Functional Description Refer to the CR, SR1 and SR2 registers in Section 4.8.6. for the bit definitions. The DDC/CI interface works as an I/O interface between the microcontroller and the DDC2Bi, EDDC or Factory alignment protocols. It receives and transmits data in Slave I2C mode using an interrupt or polled handshaking. The interface is connected to the I2C bus by a data pin (SDAD) and a clock pin (SCLD) configured as open drain. The DDC/CI interface has five internal register locations. Two of them are used for initialization of the interface: – Own Address Register OAR – Control register CR The following four registers are used during data transmission/reception: – Data Register DR – Control Register CR – Status Register 1 SR1 – Status Register 2 SR2 The interface decodes an I2C or DDC2Bi address stored by software in the OAR register and/or the EDDC address (60h/61h) as its default hardware address. After a reset, the interface is disabled. 4.8.5.2.2 I2C Modes s General description In I2C mode, the interface can operate in the following modes: – Slave transmitter/receiver Both start and stop conditions are generated by the master. The I2C clock (SCL) is always received by the interface from a master, but the interface is able to stretch the clock line. The interface is capable of recognizing both its own programmable address (7-bit) and its default hardware address (Enhanced DDC address: 60h/ 61h). The Enhanced DDC address detection may be enabled or disabled by software. It never recognizes the Start byte (01h) whatever its own address is. s Slave Mode As soon as a start condition is detected, the address is received from the SDA line and sent to the shift register; then it is compared with the programmable address of the interface or the Enhanced DDC address (if selected by software). Address not matched: the interface ignores it and waits for another Start condition. Address matched: the following events occur in sequence: – Acknowledge pulse is generated if the ACK bit is set. – EVF and ADSL bits are set. – An interrupt is generated if the ITE bit is set. Then the interface waits for a read of the SR1 register, holding the SCL line low (see Figure 67 Transfer sequencing EV1). Next, the DR register must be read to determine from the least significant bit if the slave must enter Receiver or Transmitter mode. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |