2410FA2-5-R
AI

The **2410FA2-5-R** is a specific surface-mount fuse manufactured by **Eaton (formerly Bussmann)**. It belongs to the 2410 (6125 metric) series, known for being a "Fast-Acting" (FA) Wire-in-Air (WIA) fuse.
---
### ## Technical Specifications
Below is a breakdown of the key electrical and physical attributes of the 2410FA2-5-R:
| Attribute | Specification |
|:---|:---|
| **Series** | 2410FA (Fast Acting) |
| **Current Rating** | 5 Amperes |
| **Voltage Rating (AC)** | 125 Vac |
| **Voltage Rating (DC)** | 125 Vdc |
| **Package / Case** | 2410 (6125 Metric) |
| **Interrupting Rating** | 50A @ 125Vac / 50A @ 125Vdc |
| **Typical Resistance** | 0.015 Ohms |
| **Operating Temp** | -55°C to +125°C |
| **RoHS Compliant** | Yes (Lead-Free) |
---
### ### Component Breakdown & Part Number Logic
To understand this specific part, we can deconstruct the nomenclature:
1. **2410**: Refers to the physical size in inches (0.24" x 0.10"). In metric, this is **6125** (6.1mm x 2.5mm).
2. **FA**: Stands for **Fast-Acting**. This fuse is designed to blow quickly when an overcurrent occurs, protecting sensitive downstream electronics.
3. **2**: This refers to the specific design version or termination style (Silver-plated brass endcaps).
4. **5**: Represents the **Current Rating** (5 Amps).
5. **-R**: Indicates that the part is **RoHS compliant**.
---
### ### Key Features and Applications
#### **Features**
* **Wire-in-Air Design:** This construction provides excellent inrush current withstand capability and high reliability.
* **Surface Mount:** Compatible with automated pick-and-place assembly and infrared/vapor phase reflow soldering.
* **Safety Approvals:** Typically UL Recognized and CSA Certified.
#### **Common Applications**
* **LCD Monitors & Backlight Inverters:** Protecting the power rails of display panels.
* **Server Power Supplies:** Used on secondary side circuits.
* **Medical Equipment:** General circuit protection in portable devices.
* **Battery Chargers:** Preventing thermal runaway or fire in the event of a component failure.
---
### ### Comparison: Fast-Acting vs. Time-Delay
The **FA** in 2410FA2-5-R is critical. If your circuit has high "inrush" currents (like a motor starting up), a Fast-Acting fuse might blow prematurely. However, for digital logic boards or power supplies where a fault must be cleared instantly to prevent fire or further damage, Fast-Acting is the preferred choice.
- ⤷
What is the difference between the 2410FA and the 2410TD (Time-Delay) series?
- ⤷ What are the recommended soldering profiles for this 6125 metric package?
- ⤷ Can this fuse be used in automotive applications requiring AEC-Q200 qualification?