Electronic Components Datasheet Search
  English  ▼
ALLDATASHEET.NET

X  

  • 61F-081-R

  • AI
    The **61F-G1-R** (often associated with the Omron 61F series) is a **Plug-in Level Controller** used primarily for automatic water supply and drainage control. The suffix "-R" typically indicates the inclusion of a relay unit or specific voltage requirements. Below is a breakdown of its electronic components, specifications, and functions. --- ### 1. Key Component Overview The 61F-G1-R acts as a logical switch that triggers based on the electrical conductivity of liquids. | Component | Function | | :--- | :--- | | **Internal Transformer** | Steps down the AC input voltage to a safe 8V or 24V AC for the electrodes. | | **Electrode Terminals** | Connects to the sensing rods (E1, E2, E3) placed in the liquid. | | **Electromagnetic Relay** | The output mechanism that switches the pump or motor on/off. | | **Rectifier/Comparator Circuit** | Processes the micro-current from the electrodes to determine if the circuit is closed. | | **LED Indicators** | Visual feedback showing power status and relay operation. | --- ### 2. Technical Specifications Common technical parameters for the 61F series: * **Supply Voltage:** 110/220V AC (50/60 Hz). * **Inter-electrode Voltage:** 8V AC (low voltage ensures safety and prevents electrolysis). * **Operating Resistance:** 0 to approx. 4 kΩ. * **Output:** Relay contact, 5A at 250V AC (Resistive load). * **Response Time:** 80 ms maximum for operation; 160 ms maximum for release. --- ### 3. Electronic Operating Principle The device operates on the **Conductivity Principle**: 1. **Sensing:** The controller applies a small AC voltage between a common electrode (E3) and sensing electrodes (E1/E2). 2. **Circuit Completion:** When liquid touches the electrodes, a small current flows through the liquid. 3. **Signal Processing:** An internal transistor or comparator circuit detects this current and energizes the internal relay. 4. **Hysteresis (Level Control):** By using two sensing points (High/Low), the device prevents "chattering" (rapid cycling) of the pump when the water surface is turbulent. --- ### 4. Wiring and Terminal Layout (Typical) Most 61F units use an 8-pin or 11-pin base. ```text Terminal Pinout (Example): 1 & 8: Power Supply Input (e.g., 220VAC) 2, 3, 4: Relay Output (Common, NO, NC) 5: Electrode E1 (High Level - Stop/Start) 6: Electrode E2 (Low Level - Common/Reference) 7: Electrode E3 (Ground/Common) ``` --- ### 5. Maintenance and Troubleshooting * **Scale Buildup:** If the electrodes are covered in lime or rust, the electronic circuit won't "see" the water. * **Relay Failure:** If you hear a "clicking" sound but the pump doesn't start, the internal relay contacts may be burnt. * **Voltage Drops:** Ensure the supply voltage matches the coil rating (110V vs 220V) to prevent internal transformer burnout.
    ✨ Follow-up Questions
    • ⤷ What is the difference between the G1 and the G-series models?
    • ⤷ How do I wire the 61F-G1-R for automatic drainage vs. water supply?
    • ⤷ Can this controller be used with non-conductive liquids like oil?