CRE10RRD-M0S-R
AI

The **CRE10RRD-M0S-R** is a specific type of **Rotary Coded Switch** manufactured by **Copal Electronics** (now Nidec Components). These switches are used to convert a physical rotational position into a binary output, typically for setting addresses or modes on a circuit board.
---
### 1. Technical Specifications
The part number can be broken down to understand its physical and electrical characteristics:
| Feature | Specification |
| :--- | :--- |
| **Part Series** | CRE Series (Coded Rotary Switches) |
| **Positions** | 10 Positions (0-9) |
| **Output Code** | Real Binary Coded Decimal (BCD) |
| **Actuator Type** | Recessed / Flush (Screwdriver slot) |
| **Mounting Type** | Surface Mount (SMD / SMT) |
| **Terminal Shape** | Gull-wing (R-bend) |
| **Operating Temperature** | -40°C to +85°C |
---
### 2. Pinout and Logic Table
As a BCD (Binary Coded Decimal) switch with 10 positions, it typically has 4 data pins plus a common pin. The output corresponds to the binary representation of the dial number.
**Truth Table Example:**
| Position | Pin 1 (1) | Pin 2 (2) | Pin 3 (4) | Pin 4 (8) |
| :--- | :--- | :--- | :--- | :--- |
| **0** | OFF | OFF | OFF | OFF |
| **1** | **ON** | OFF | OFF | OFF |
| **2** | OFF | **ON** | OFF | OFF |
| **5** | **ON** | OFF | **ON** | OFF |
| **9** | **ON** | OFF | OFF | **ON** |
---
### 3. Key Electronic Characteristics
#### A. Contact Rating
* **Switching:** Usually 5V DC, 100mA.
* **Non-Switching:** Up to 50V DC, 100mA.
* The low current rating indicates this is a **signal-level switch**, not intended to drive high-power loads directly.
#### B. Durability and Sealing
* **Washability:** These switches are often "process sealed" (using an O-ring), meaning they can withstand aqueous cleaning or wave soldering processes without internal contamination.
* **Mechanical Life:** Typically rated for 10,000 to 20,000 steps.
#### C. Footprint (SMD)
* The "M0S" designation refers to the specific physical dimensions and the "R" at the end usually denotes **Tape and Reel** packaging for automated pick-and-place machines.
---
### 4. Common Applications
* **Industrial Controls:** Setting a unique ID or address for a device on a bus (like RS-485 or CAN bus).
* **Telecommunications:** Mode selection or configuration settings.
* **Security Systems:** Manual hardware-based code entry or zone settings.
---
- ⤷What is the difference between 'Real' and 'Complementary' BCD codes in rotary switches?
- ⤷ How should I design the pull-up resistors for this switch in a microcontroller circuit?
- ⤷ Can this switch be used for AC voltage applications?