CRE10RRD-P1S-R
AI

The **CRE10RRD-P1S-R** is a specific type of electromechanical component, categorized as a **Rotary Coded Switch**. These components are commonly used to set binary or hexadecimal values manually on a printed circuit board (PCB).
---
## 1. Technical Specifications
Below are the primary electrical and mechanical specifications for this component:
| Feature | Specification |
| :--- | :--- |
| **Manufacturer** | C&K (Now part of Littelfuse) |
| **Switch Type** | Rotary Coded Switch |
| **Number of Positions** | 10 (Decimal / BCD) |
| **Output Code** | Binary Coded Decimal (BCD) |
| **Actuator Type** | Raised Shaft (with slot for screwdriver) |
| **Mounting Type** | Through-Hole (Right Angle) |
| **Contact Rating** | 100mA @ 50V DC (Non-switching) |
| **Operating Force** | 400 gf-cm |
---
## 2. Key Internal Electronic Parts & Materials
The functionality of the CRE10RRD-P1S-R relies on several internal physical elements:
### A. The Rotor (Actuator)
The "P1S" in the part number indicates a specific actuator style. It is a **raised shaft** that allows a user to turn the switch to one of 10 positions (0 through 9).
### B. The Coding Disk
Internally, a conductive disk is etched with a specific pattern. As the rotor turns, the disk completes a circuit between the common pin and the four output pins (1, 2, 4, and 8).
* **Example:** If set to "3", pins 1 and 2 are connected to the Common pin ($1+2=3$).
### C. Contact System
* **Base Material:** Copper alloy.
* **Plating:** Gold over Nickel. Gold plating is critical for low-voltage electronic signals as it prevents oxidation and ensures reliable contact over the component's lifespan.
### D. Housing
The body is typically made of high-temperature thermoplastic (PPS or LCP) to withstand wave soldering temperatures.
---
## 3. Terminal Layout (Right Angle)
The **"RRD"** designation indicates a **Right Angle** orientation. This means the pins are bent at 90 degrees so the switch can be mounted on the edge of a PCB, allowing the user to adjust the dial from the side of the device enclosure.
---
## 4. Typical Applications
* **Address Setting:** Assigning a unique ID to a device on a bus (like RS-485 or CAN).
* **Mode Selection:** Selecting between different operating programs in industrial controllers.
* **Configuration:** Setting baud rates or timeout intervals on legacy hardware.
- ⤷
What is the difference between BCD and Hexadecimal coding in these switches?
- ⤷ Can this switch be used for AC power applications?
- ⤷ What is the mechanical life expectancy of the CRE series switches?