The **DRS-G-R/E2** is a specific model of a **magnetic reed sensor**, typically used in industrial automation for position sensing, limit switching, and pneumatic cylinder control. It is characterized by its high sensitivity and durability in harsh environments.
---
### 1. Key Technical Specifications
The following table summarizes the primary electronic characteristics of the DRS-G-R/E2:
| Parameter | Specification | Details |
| :--- | :--- | :--- |
| **Switching Type** | Reed Switch | SPST (Normally Open) |
| **Operating Voltage** | 5V – 240V AC/DC | Wide voltage compatibility |
| **Switching Current** | 100 mA (Max) | For signaling/low-power relay control |
| **Contact Capacity** | 10W | Maximum power rating |
| **Internal Voltage Drop** | ≤ 2.5V | Voltage loss across the sensor |
| **Response Time** | ≤ 1.0 ms | High-speed switching |
| **Indicator** | Red LED | Visual status for "On" state |
---
### 2. Electronic Components & Design
The device is composed of several critical internal and external parts:
#### A. The Reed Switch Element
The heart of the sensor is a glass-encapsulated reed switch. It consists of two ferromagnetic blades that move together to close the circuit when a magnetic field (from a piston or external magnet) is present.
#### B. LED Indicator Circuit
An internal **Light Emitting Diode (LED)** is wired in series with the switch. This provides an immediate visual diagnostic:
* **LED On:** The magnetic field is detected, and the circuit is closed.
* **LED Off:** No magnetic field detected, or there is a power failure.
#### C. Protection Components
To ensure longevity in industrial settings, the DRS-G-R/E2 often includes:
* **Varistors/Diodes:** To protect the contacts from back-EMF (voltage spikes) caused by inductive loads.
* **Encapsulation:** The internal electronics are potted in epoxy resin to protect against vibration, moisture, and dust.
#### D. Connection Interface
The "E2" designation usually refers to the wiring configuration:
* **Type:** 2-wire configuration.
* **Polarity:** Non-polar (though the LED may require correct orientation depending on the specific sub-model wiring).
---
### 3. Wiring Diagram (Simplified)
When integrating this sensor into a PLC or Relay circuit, the connection follows this logic:
```text
[Power Source (+)] ---- [Load (Relay/PLC Input)] ---- [DRS-G-R/E2 Sensor] ---- [Power Source (-)]
```
> **Note:** Because this is a 2-wire sensor, there is a small "leakage current" even when the switch is off (to power the LED if applicable) and a "voltage drop" when the switch is on. Ensure your PLC input threshold is compatible.
- ⤷
How does the voltage drop of 2.5V affect PLC input compatibility?
- ⤷ What are the primary differences between the DRS-G and the D-M9 series sensors?
- ⤷ Can this sensor be used directly with high-power AC motors?