F03-13
AI

The **F03-13** is a specific part number associated with the **Omron Sensing Band**, primarily used for liquid leakage detection systems. It is an accessory designed to be paired with Omron leak detectors (such as the K7L or 61F series).
Below is a detailed breakdown of the electronic and mechanical characteristics of the F03-13.
---
### 1. Overview and Construction
The F03-13 is a point-sensor or "Sensing Band" designed to detect the presence of water or other conductive liquids. Unlike standard wires, it is engineered to maximize surface area contact with moisture.
| Component | Material/Specification |
| :--- | :--- |
| **Core Material** | Stainless Steel (SUS304) |
| **Insulator** | Polyethylene |
| **Detection Method** | Electrical Conductivity |
| **Standard Lengths** | 1m, 5m, 10m, 20m, 50m |
### 2. Electronic Working Principle
The F03-13 operates based on the principle of **Conductivity**.
* **Open Circuit:** Under dry conditions, the air or the dry band acts as an insulator between the conductive stainless steel cores. The resistance is extremely high (infinite).
* **Closed Circuit:** When liquid contacts the band, the liquid creates a bridge between the electrodes. This lowers the resistance significantly.
* **Signal Output:** The connected Leakage Sensor (e.g., K7L) detects this drop in resistance and triggers an alarm or switches a relay.
### 3. Key Electronic Specifications
These specifications are critical when integrating the band into a control system:
| Feature | Description |
| :--- | :--- |
| **Operating Temperature** | -15°C to +60°C |
| **Resistance** | Approx. 1 mΩ per meter |
| **Dielectric Strength** | 1,000 VAC for 1 minute |
| **Insulation Resistance** | 10 MΩ minimum (between electrodes) |
### 4. Comparison with F03-16 (High Sensitivity)
Omron produces several versions of these bands. It is important to distinguish the F03-13 from its counterparts.
| Feature | F03-13 (Standard) | F03-16 (High Sensitivity) |
| :--- | :--- | :--- |
| **Electrode Distance** | Wider spacing | Narrow spacing |
| **Primary Use** | General water leakage | High-speed detection/small droplets |
| **Environment** | Floor mounting | Ceilings or tight spaces |
---
### 5. Installation Wiring Example
The F03-13 is typically connected to a terminal block using an **F03-14** (Terminal Block for sensing bands).
```text
[ Controller (K7L) ] <------> [ F03-14 Terminal ] <------> [ F03-13 Sensing Band ]
(DC/AC) (Connection) (Sensing Area)
```
- ⤷
What are the compatible Omron controllers for the F03-13 band?
- ⤷ How do you test if an F03-13 band is functioning correctly using a multimeter?
- ⤷ Can the F03-13 be used to detect non-conductive liquids like oil?