FLM-44-R
AI

The **FLM-420-RLV1-S** (often referred to in series shorthand as FLM-44-R types) is an **Octo-relay Interface Module** typically used in Bosch fire alarm systems (LSN improved version). It is designed to provide multiple physical relay outputs for controlling external equipment.
---
## 1. Technical Specifications
The following table outlines the key electronic parameters for this module:
| Parameter | Specification |
| :--- | :--- |
| **Input Voltage** | 15 V DC to 33 V DC (LSN part) |
| **Max. Current Consumption** | Approx. 6.35 mA (at 24 V DC) |
| **Number of Relays** | 8 (Octo-relay) |
| **Contact Rating** | 2 A @ 30 V DC / 0.5 A @ 125 V AC |
| **Interface** | LSN (Local Security Network) |
| **Operating Temperature** | -20 °C to +65 °C |
---
## 2. Core Electronic Components
### A. The Relay Array
The module features eight independent change-over (Form C) relays. These are mechanical switches controlled electronically by the fire panel.
* **Isolation:** The relays provide galvanic isolation between the fire panel's internal logic and the external load (e.g., elevators, fire doors, fans).
* **Switching Capacity:** Designed for low-voltage signal switching rather than high-current power distribution.
### B. Addressing Switches (Rotary Switches)
The module uses three rotary switches to define its unique address on the LSN loop.
* **Manual Addressing:** You can set the address from 001 to 254.
* **Auto-Addressing:** If set to 000, the fire panel automatically assigns an address.
### C. LSN Controller Chip
The "brain" of the module is an integrated circuit (IC) that communicates with the Fire Alarm Control Panel (FACP). It handles:
* **Data Transmission:** Receiving commands to trigger specific relays.
* **Status Monitoring:** Reporting the health and connectivity of the module back to the panel.
---
## 3. Terminal Connections
The module's PCB includes specific terminals for wiring:
1. **LSN Terminals:** `LSN a1/b1` and `LSN a2/b2`. These carry both power and data from the fire panel loop.
2. **Relay Terminals:** Each relay has three contacts:
* **NC** (Normally Closed)
* **C** (Common)
* **NO** (Normally Open)
---
## 4. Key Features
* **Fail-Safe Mode:** The module can be programmed to maintain its current state or switch to a predefined state if communication with the panel is lost.
* **LED Indicators:** Typically features an integrated LED to signal communication status or internal faults.
* **DIN Rail Mounting:** The internal PCB is usually housed in a casing compatible with standard 35mm DIN rails.
- ⤷What is the difference between the FLM-420-RLV1-S and other FLM series modules?
- ⤷ How do you wire a fire door release to an FLM-44-R relay?
- ⤷ What are the maximum current limits for the LSN loop when using multiple relay modules?