### 1. Functional Overview
The FLM-C1-R serves as an interface between the fire alarm system's data loop and external equipment. It provides a dry contact relay output that can be programmed to trigger specific actions when the panel detects an event.
### 2. Technical Specifications
| Feature | Specification |
| :--- | :--- |
| **Module Type** | Addressable Relay Module |
| **Input Voltage (LSN)** | 15 V DC to 33 V DC |
| **Max. Current Consumption** | Approx. 1.1 mA |
| **Relay Contact Type** | Form C (Change-over) |
| **Contact Rating** | 1 A at 30 V DC / 0.5 A at 125 V AC |
| **Address Setting** | Rotary switches or Auto-addressing |
| **Operating Temperature** | -20 °C to +50 °C |
### 3. Key Electronic Components
#### A. LSN Interface (Local Security Network)
The module communicates with the main control panel via an LSN bus. This interface handles:
* **Data Transmission:** Receiving commands to toggle the relay.
* **Power:** Drawing the small amount of current needed to operate the onboard logic.
#### B. The Relay (Electromechanical)
The core of the unit is a physical relay.
* **Terminals:** It typically provides three terminals: **COM** (Common), **NC** (Normally Closed), and **NO** (Normally Open).
* **Isolation:** The relay provides galvanic isolation, meaning the high-voltage/high-current circuit being switched is electrically separated from the sensitive fire alarm data loop.
#### C. Addressing Mechanism
Most versions feature **Rotary Switches** on the PCB. These allow the technician to manually set a unique decimal address (e.g., 001 to 254) so the control panel can identify and control that specific module.
---
### 4. Common Applications
In an electronic system, the FLM-C1-R is used to control:
* **Elevator Recall:** Sending a signal to the elevator controller to return to the ground floor.
* **HVAC Shutdown:** Turning off fans to prevent the spread of smoke.
* **Door Release:** Releasing magnetic door holders to close fire doors.
* **Strobe/Siren Activation:** Triggering non-addressable notification appliances.
### 5. Wiring Diagram Logic
The module generally has two sets of connections:
1. **LSN In/Out:** Connected to the fire panel signaling line circuit.
2. **Relay Output:** Connected to the external device power source and the device itself.
- ⤷