FNQ-R-4-R1
AI

The **FNQ-R-4** is a high-performance, current-limiting time-delay fuse belonging to the **Bussmann CC-TRON™** series. These fuses are specifically designed for branch circuit protection, particularly for inductive loads like transformers and motors.
---
## 🛠️ Technical Specifications
Below are the primary electronic and physical specifications for the FNQ-R-4:
| Feature | Specification |
| :--- | :--- |
| **Current Rating** | 4 Amperes |
| **Voltage Rating (AC)** | 600 Vac |
| **Interrupting Rating** | 200,000 Amps RMS Symmetrical |
| **Class** | Class CC |
| **Fuse Type** | Time-Delay (Slow Blow) |
| **Dimensions** | 13/32" x 1-1/2" (10.3 x 38.1 mm) |
| **Material** | Melamine tube with Nickel-plated brass endcaps |
---
## 💡 Key Electronic Characteristics
### 1. High Rejection Feature
The "R" in the part number signifies a **rejection tip**. This physical feature prevents the installation of lower-rated fuses (like standard midget fuses) into a Class CC fuse holder, ensuring that the circuit remains protected by a fuse capable of handling high-fault currents.
### 2. Time-Delay Functionality
Because it is a "Time-Delay" fuse, it can withstand high **inrush currents** (temporary surges) without blowing. This is critical for electronic components like:
* **Control Transformers:** Which draw massive current for a fraction of a second upon startup.
* **Solenoids:** Which require a burst of energy to actuate.
### 3. Current Limitation
The FNQ-R-4 is "Current Limiting." In the event of a short circuit, the fuse reacts so quickly that it interrupts the current before it reaches its full destructive peak. This protects downstream electronic components from thermal and magnetic stress.
---
## 🔌 Typical Applications
The FNQ-R-4 is commonly found in industrial control panels and electronic systems involving:
* **Branch Circuit Protection:** Safe distribution of power to sub-circuits.
* **Motor Control Circuits:** Protecting contactors and relays.
* **Inductive Loads:** Ideal for circuits where "nuisance tripping" is common with fast-acting fuses.
---
## ⚠️ Comparison: FNQ vs. FNQ-R
| Feature | FNQ (Standard) | FNQ-R (Class CC) |
| :--- | :--- | :--- |
| **Rejection Tip** | No | Yes |
| **Interrupting Rating** | 10,000 Amps | 200,000 Amps |
| **Usage** | Supplemental protection | Branch circuit protection |
- ⤷
What is the difference between a Time-Delay and a Fast-Acting fuse in transformer protection?
- ⤷ Can an FNQ-R-4 fuse be used in a standard 13/32\ midget fuse holder?
- ⤷ How does the 200kA interrupting rating impact circuit safety?