FNS-4W1-R
AI

The **FNS-4W1-R** is a specific model of a **water leak detection sensor** (often manufactured by companies like FineTek). It is designed to detect the presence of conductive liquids (water) to prevent damage in sensitive environments like data centers, laboratories, or industrial facilities.
---
### 1. Key Technical Specifications
The following table outlines the primary electronic and physical characteristics of the FNS-4W1-R sensor:
| Feature | Specification |
| :--- | :--- |
| **Detection Method** | Electrical Conductivity (Leak sensing cable) |
| **Input Voltage** | 12V to 24V DC |
| **Power Consumption** | Low (approx. 30-50mA depending on state) |
| **Output Signal** | Relay Contact (SPDT) - Normal Open/Normal Closed |
| **Contact Rating** | 1A @ 24VDC or 0.5A @ 125VAC |
| **Response Time** | < 1 second |
| **Operating Temperature** | -20°C to +75°C |
---
### 2. Main Electronic Components
The device functions as an interface module that connects a sensing cable to a monitoring system (PLC or Alarm).
* **Sensing Interface:** Uses a weak electrical current sent through a specialized sensing cable. When water touches the cable, it completes a circuit (bridging the gap between wires), which the electronic module detects.
* **Signal Processor:** An internal IC analyzes the resistance change. It is designed to distinguish between actual leaks and high humidity to prevent false alarms.
* **Relay Output:** The "R" in the model name typically signifies a **Relay** output. This allows the device to act as a switch to trigger external sirens, shut off valves, or notify a Building Management System (BMS).
* **LED Indicators:**
* **Power LED:** Indicates the module is receiving DC power.
* **Alarm/Leak LED:** Lights up when a leak is detected or when there is a continuity break in the sensing cable.
---
### 3. Wiring Configuration
The unit typically features a terminal block for easy integration:
```markdown
Terminal 1-2: Power Input (V+ and V-)
Terminal 3-4: Sensing Cable Input
Terminal 5-6-7: Relay Outputs (Common, NO, NC)
```
---
### 4. Applications
The FNS-4W1-R is commonly integrated into the following systems:
1. **Server Rooms:** Placed under raised floors to detect A/C condensation leaks.
2. **Clean Rooms:** Monitoring chemical or water transport lines.
3. **Basements/Storage:** Protecting high-value inventory from flooding.
- ⤷
How do you test the sensitivity of the FNS-4W1-R sensor?
- ⤷ What is the maximum length of the sensing cable supported by this module?
- ⤷ Can this sensor distinguish between water and non-conductive liquids like oil?