The **FRT-55-R/Q** refers to a high-precision, low-profile **Force Transducer (Load Cell)** manufactured by Kyowa. These sensors are specifically designed for measuring compression and tension forces in environments where space is limited and high reliability is required.
---
### 1. Key Technical Specifications
| Feature | Specification Details |
| :--- | :--- |
| **Rated Capacity** | Typically around 50N to 500N (depending on specific model suffix) |
| **Bridge Resistance** | 350 Ω (Standard Wheatstone Bridge) |
| **Sensitivity** | Approx. 1.0 to 2.0 mV/V |
| **Non-linearity** | Within ±0.1% to ±0.5% RO |
| **Operating Temp** | -10°C to +70°C (Compensated range) |
| **Construction** | Stainless Steel or High-strength Aluminum Alloy |
---
### 2. Internal Electronic Components
The FRT-55-R/Q is a passive resistive sensor. Its operation is based on the following electronic elements:
#### A. Strain Gauges
The heart of the part consists of **Bonded Foil Strain Gauges**. These are resistors arranged in a specific pattern. When a force is applied to the metal body of the sensor, the gauges deform, causing their electrical resistance to change.
#### B. Wheatstone Bridge Circuit
The strain gauges are wired into a **Full Bridge (Wheatstone Bridge)** configuration. This allows the sensor to:
* Maximize the signal output (sensitivity).
* Provide thermal compensation (canceling out resistance changes caused by temperature fluctuations).
#### C. Compensation Resistors
Inside the casing, there are small "trim" resistors. These are used during factory calibration to:
* **Zero Balance:** Ensure the output is 0V when no load is applied.
* **Span Temperature Compensation:** Ensure the sensitivity remains constant across different temperatures.
---
### 3. Wiring Diagram (Standard 4-Wire)
The sensor typically uses a 4-conductor shielded cable. The color coding is generally standardized for Kyowa FRT series:
| Wire Color | Function | Description |
| :--- | :--- | :--- |
| **Red** | Input (+) | Positive Excitation Voltage (typically 2V - 10V DC) |
| **White** | Input (-) | Negative Excitation / Ground |
| **Green** | Output (+) | Positive Signal (millivolts) |
| **Blue** | Output (-) | Negative Signal (millivolts) |
---
### 4. Application Integration
To use the FRT-55-R/Q in an electronic system, it must be paired with:
1. **Strain Amplifier:** Since the output is in millivolts (mV), it requires a high-gain amplifier (like a HX711 for DIY or a Kyowa DPM series for industrial use).
2. **ADC (Analog to Digital Converter):** To convert the analog voltage into a digital value for a microcontroller or PLC.
3. **Regulated Power Supply:** The accuracy of the sensor depends directly on the stability of the Excitation Voltage.
- ⤷
What is the maximum excitation voltage recommended for this sensor?
- ⤷ How do you calibrate the FRT-55-R/Q using a microcontroller?
- ⤷ What are the physical mounting requirements for the R/Q variant?