FTS-3B-R/BN
AI

The **FTS-3B-R/BN** is a specific model within the series of **Float Type Level Switches** (often associated with manufacturers like Finetek). These devices are used to detect liquid levels in tanks or sumps to control pumps or trigger alarms.
---
## 1. Technical Specifications
The "R/BN" suffix typically denotes specific material and contact configurations. Below is a breakdown of the electronic and mechanical characteristics:
| Feature | Specification |
| :--- | :--- |
| **Contact Type** | Microswitch (SPDT - Single Pole Double Throw) |
| **Contact Capacity** | 10A / 250VAC (Resistive Load) |
| **Float Material** | Polypropylene (PP) or Neoprene (depending on sub-spec) |
| **Cable Material** | BN (Usually High-quality Neoprene or Rubber) |
| **Operating Temp** | -10°C to 80°C |
| **Max Pressure** | 2 kg/cm² |
---
## 2. Internal Electronic Components
The device operates on a simple but reliable electromechanical principle. It does not contain complex integrated circuits (ICs), but rather high-durability discrete components:
### A. The Microswitch
The heart of the FTS-3B is a **Microswitch**.
- **Function:** When the float tilts (due to rising or falling liquid), an internal weight or rolling ball moves to actuate the switch plunger.
- **Wiring:** Being an SPDT switch, it provides three connection points:
1. **COM (Common)**
2. **NO (Normally Open)** - Closes when the float is up.
3. **NC (Normally Closed)** - Opens when the float is up.
### B. The Cable (BN Specification)
The "BN" designation often refers to the **Chloroprene (Neoprene)** cable.
- **Electronic Role:** It provides high insulation resistance and is designed to withstand continuous immersion in water or oily liquids without the outer jacket becoming brittle or leaking current.
---
## 3. Wiring Diagram Logic
To integrate this into an electronic control system (like a PLC or a Motor Starter), the wiring typically follows this logic:
```mermaid
graph LR
A[Power Source] --> B[Common Wire]
B --> C{Microswitch}
C -- Float Up --> D[NO Contact -> Pump Off/Alarm On]
C -- Float Down --> E[NC Contact -> Pump On/Alarm Off]
```
### Wiring Colors (Standard)
* **Blue:** Common (COM)
* **Brown:** Normally Open (NO) - Closes on rise.
* **Black:** Normally Closed (NC) - Opens on rise.
---
## 4. Applications
- **Wastewater Management:** Controlling submersible pumps in sumps.
- **Industrial Tanks:** High/Low-level alarm triggering.
- **Electronic Integration:** Acting as a digital input (DI) for a PLC to manage automated filling cycles.
- ⤷How do I wire the FTS-3B to a 220V water pump?
- ⤷ What is the difference between the 'BN' cable and the standard 'PVC' cable?
- ⤷ How do I test if the internal microswitch is still functional?