Based on your query, the **FTS-N2-R/BN** appears to be a specific model variant of a **Thermal Flow Sensor** (likely from the FTS series by manufacturers like *GEMS Sensors* or similar industrial automation brands). These devices are used to monitor the flow rate and temperature of liquids.
Below is the breakdown of its electronic components, specifications, and wiring structure.
---
### 1. Functional Overview
The FTS-N2-R/BN is an electronic flow switch that operates on the **calorimetric principle**. It uses two thermistors (sensors) inside the probe: one is heated, and the other measures the fluid temperature. The cooling effect of the flowing fluid is used to determine the flow rate.
### 2. Technical Specifications
| Feature | Specification Details |
| :--- | :--- |
| **Operating Principle** | Calorimetric (Thermal) |
| **Switching Output** | Relay (indicated by the **-R** in the model code) |
| **Housing Material** | Nickel-plated brass (indicated by **BN**) |
| **Connection Type** | Typically M12 Circular Connector or Hardwired Cable |
| **Media Compatibility** | Water and water-based liquids |
| **Pressure Rating** | Usually up to 100 bar (verify with datasheet) |
---
### 3. Key Electronic Parts
The internal circuitry consists of several critical stages:
1. **Sensing Element:** A pair of matched NTC or PTC thermistors housed in the metal tip.
2. **Signal Processing (ASIC):** An internal integrated circuit that compares the temperature differential between the sensors and converts it into a standardized signal.
3. **Adjustment Potentiometers:** Most units feature "Teach-In" buttons or screw-potentiometers to set the setpoint (the flow rate at which the switch triggers).
4. **Output Relay:** A physical or solid-state relay that opens or closes a circuit when the flow drops below or rises above the setpoint.
5. **LED Indicators:**
* **Red:** Flow below setpoint (Switch off).
* **Yellow/Amber:** Flow at setpoint.
* **Green:** Flow exceeds setpoint.
---
### 4. Wiring and Pinout
Since this model features a **Relay (-R)** output, the wiring typically follows this logic:
| Pin/Wire Color | Function | Description |
| :--- | :--- | :--- |
| **Brown** | +VDC | Power Supply (typically 24V DC) |
| **Blue** | 0V / GND | Ground |
| **White** | Relay COM | Common contact for the switch |
| **Black** | Relay NO/NC | Normally Open or Normally Closed contact |
---
### 5. Application Usage
* **Pump Protection:** Ensuring a pump does not run dry.
* **Cooling Systems:** Monitoring the flow of coolant in welding machines or induction furnaces.