HTS-01-R/BN
AI

The **HTS-01-R/BN** is a high-precision, industrial-grade humidity and temperature sensor probe, typically utilized in environmental monitoring systems and climate control applications.
---
### 1. General Specifications
This sensor is designed for durability and accuracy. Below are the primary electronic and physical characteristics:
| Feature | Specification |
| :--- | :--- |
| **Model** | HTS-01-R/BN |
| **Sensor Type** | Digital Capacitive (Humidity) / NTC or RTD (Temperature) |
| **Connection Type** | Circular Connector (BN series often denotes specific pin configurations) |
| **Interface** | Usually I2C or RS485 (depending on the internal transmitter) |
| **Housing Material** | Stainless Steel or High-grade Polymer |
| **Protection Rating** | IP65 or higher (Dust and Water-resistant) |
---
### 2. Core Electronic Components
The device is comprised of several critical electronic stages:
* **Sensing Element:**
* **Humidity:** Uses a polymer capacitive sensor that changes capacitance based on the dielectric constant of the air.
* **Temperature:** Employs a high-precision thermistor (NTC) or a Platinum Resistance Thermometer (PT100/PT1000).
* **Signal Conditioning (ASIC):**
* Includes an internal Analog-to-Digital Converter (ADC).
* Applies factory-calibrated coefficients to ensure linear output.
* **Protection Circuitry:**
* Integrated TVS (Transient Voltage Suppressors) to protect against electrostatic discharge (ESD) and voltage spikes.
* Reverse polarity protection to prevent damage during installation.
---
### 3. Pinout and Wiring (Typical)
While specific colors can vary by manufacturer, the BN-type connector usually follows this 4-wire standard:
| Pin Number | Function | Description |
| :--- | :--- | :--- |
| 1 | VCC | Power Supply (typically 3.3V - 5V or 12V-24V for RS485 versions) |
| 2 | GND | Ground |
| 3 | DATA / A | Digital Data line or RS485 A (+) |
| 4 | CLK / B | Clock line or RS485 B (-) |
---
### 4. Key Application Areas
* **HVAC Systems:** Monitoring building automation and air quality.
* **Data Centers:** Ensuring server racks stay within thermal and moisture limits.
* **Greenhouses:** Controlling irrigation and ventilation based on vapor pressure deficit (VPD).
* **Cold Chain:** Monitoring perishable goods during transport or storage.
- ⤷
What is the specific communication protocol (I2C vs Modbus) for this model?
- ⤷ How do I calibrate the HTS-01-R/BN for high-humidity environments?
- ⤷ What is the operating voltage range for the HTS-01-R/BN?