JR28-R-4MMP115
AI

The **JR28-R-4MMP115** is a specific model of a **Thermal Overload Relay**, typically used in industrial motor control circuits to protect motors from overheating and phase failures. It is often a direct equivalent or compatible part for the Schneider Electric TeSys D series (LRD style).
---
### ## Technical Specifications
The following table outlines the primary electrical characteristics of the device:
| Feature | Specification |
| :--- | :--- |
| **Product Type** | Thermal Overload Relay |
| **Series** | JR28 (TeSys D Compatible) |
| **Current Setting Range** | 80A to 93A (Standard for this frame size) |
| **Control Voltage** | 115V AC (For auxiliary contacts/tripping logic) |
| **Frequency** | 50/60 Hz |
| **Mounting** | Direct mounting to LC1D contactors or DIN rail |
| **Trip Class** | Class 10A (Standard industrial trip speed) |
---
### ## Core Electronic & Mechanical Components
The device functions through a combination of electromechanical and thermal sensing elements:
1. **Bimetallic Strips:**
The heart of the unit. As current flows through these strips, they heat up. Because they consist of two different metals, they bend at a predictable rate. If the current exceeds the set threshold, the physical displacement triggers the internal mechanism.
2. **Differential Mechanism (Phase Failure Protection):**
It monitors the relative position of all three bimetallic strips. If one phase drops (current becomes zero), the differential slide moves unevenly, causing the relay to trip faster than a standard overload condition.
3. **Auxiliary Contacts:**
* **95-96 (NC):** Normally Closed contact used in series with the contactor coil. It opens during a fault to kill power.
* **97-98 (NO):** Normally Open contact used for signaling or alarm lights to indicate a fault has occurred.
4. **Adjustment Dial:**
A calibrated potentiometer-style dial on the front face that allows the user to set the exact full-load current (FLC) of the motor.
---
### ## Operational Modes
The device features a multi-function selector on the front panel:
* **H (Hand/Manual):** After a trip, the user must physically press the Reset button to restart the circuit.
* **A (Automatic):** The relay will automatically reset itself once the bimetallic strips have cooled down.
* **Stop/Test Button:** Allows for manual interruption of the circuit to verify that the auxiliary contacts are functioning correctly.
---
### ## Wiring Diagram (Typical)
```mermaid
graph TD
Power_In[3-Phase Power] --> L1_L2_L3[Main Terminals]
L1_L2_L3 --> Bimetal[Bimetallic Strips]
Bimetal --> T1_T2_T3[Motor Output]
subgraph Control_Circuit
NC_95_96[95-96 NC Contact] -- Series Connection --> Contactor_Coil
NO_97_98[97-98 NO Contact] -- Alarm --> Indicator_Light
end
```
---
- ⤷What is the difference between Class 10 and Class 20 trip settings?
- ⤷ How do I wire the 115V control circuit to this relay?
- ⤷ Can this relay be used with a 230V contactor coil?