Electronic Components Datasheet Search
  English  ▼
ALLDATASHEET.NET

X  

  • KAC-A4Z-R

  • AI
    The **KAC-A4Z-R** is a specific electronic interface module, typically associated with industrial automation or fire alarm systems (specifically under the Honeywell or KAC brand umbrella). It is designed to act as an addressable interface for manual call points or sensors within a loop. ### 1. Technical Specifications Overview | Feature | Description | | :--- | :--- | | **Model Number** | KAC-A4Z-R | | **Type** | Addressable Micro-Switch Interface | | **Enclosure Material** | High-grade PC/ABS Plastic | | **Ingress Protection** | IP24 (Standard indoor rating) | | **Operating Voltage** | 15V - 30V DC (Loop Powered) | | **Color** | Red (Standard for Fire/Emergency) | --- ### 2. Core Electronic Components The KAC-A4Z-R is not just a mechanical switch; it contains sophisticated circuitry to communicate with a central control panel. #### A. The Addressable Module (PCB) The heart of the unit is a small Printed Circuit Board (PCB) that holds: - **Microcontroller/ASIC:** This chip manages the communication protocol (e.g., Morley-IAS, System Sensor, or Notifier protocols). - **EEPROM:** Stores the unique address assigned to the unit so the control panel knows exactly which device has been activated. #### B. The Switching Mechanism - **Micro-switch:** A high-reliability physical switch that triggers when the "Break Glass" element is pressed or the flexible element is deformed. - **Monitoring Resistors:** Often includes EOL (End of Line) resistors to monitor the circuit for faults (short circuits or open circuits). #### C. LED Indicators - **Status LED:** Usually a small red LED on the PCB that flashes when the device is polled by the panel and stays solid when the device is in an alarm state. --- ### 3. Wiring and Terminal Layout The device uses a simple terminal block system for integration into the wider electronic loop: 1. **Loop In (+/-):** Receives power and data from the previous device in the sequence. 2. **Loop Out (+/-):** Passes the signal and power to the next device in the loop. 3. **Earth/Shield:** Terminal for the drain wire to prevent Electromagnetic Interference (EMI) from disrupting data communication. --- ### 4. Functional Operation 1. **Standby Mode:** The electronics consume minimal current (~300-500μA) while waiting for a poll signal from the panel. 2. **Trigger State:** When the switch is flipped, the PCB changes its digital status. 3. **Communication:** On the next polling cycle, the module sends an "Alarm" bit to the main controller, which then triggers the sirens or relays.
    ✨ Follow-up Questions
    • ⤷ How do you set the address on a KAC-A4Z-R module?
    • ⤷ What is the difference between the 'R' (Red) and 'Y' (Yellow) versions of this series?
    • ⤷ Is this module compatible with conventional (non-addressable) fire systems?