M2AC-A1Z-R2/CE
AI

The **M2AC-A1Z-R2/CE** is a high-performance **Signal Conditioner (Transducer)** manufactured by **M-System**. It is specifically designed to convert an Alternating Current (AC) input into a standard DC output signal, providing electrical isolation between the input, output, and power supply.
Below is the breakdown of its electronic specifications and features.
---
## 1. Technical Specifications
| Feature | Specification |
| :--- | :--- |
| **Model Series** | M2 Series (Plug-in Signal Conditioners) |
| **Input Signal** | 0 – 1 A AC (Standard configuration for -A1) |
| **Output Signal** | 4 – 20 mA DC (Standard for -Z) |
| **Power Input** | 100 – 240 V AC (Indicated by -R2) |
| **Accuracy** | ±0.3% of span |
| **Response Time** | ≤ 0.5 seconds (0 – 90%) |
| **Isolation** | 3-way isolation (Input to output to power) |
| **Certification** | CE Marking (Indicated by /CE) |
---
## 2. Model Breakdown (Nomenclature)
* **M2AC**: Model name for an **AC Current Transmitter**.
* **A1**: Input Code. Typically represents **0 – 1 A AC**.
* **Z**: Output Code. Represents a **4 – 20 mA DC** current loop output.
* **R2**: Power Supply Code. Indicates a wide-range AC power input (**100 – 240 V AC**, 50/60 Hz).
* **CE**: Confirms the device meets European Safety Standards (EMC and Low Voltage Directives).
---
## 3. Standard Electronic Logic & Wiring
The device operates on a linear transformation logic: $I_{out} = f(I_{in})$. While the input is an alternating waveform, the internal circuitry rectifies and filters the signal to provide a smooth, proportional DC output.
### Terminal Connections (Typical)
| Terminal | Function | Description |
| :--- | :--- | :--- |
| **1 - 2** | Input | Connects to the Current Transformer (CT) secondary |
| **4 - 5** | Output | Connects to PLC/Controller (4-20mA) |
| **7 - 8** | Power | 100-240V AC Mains |
---
## 4. Key Electronic Features
### A. 2000V AC Isolation
The unit provides a dielectric strength of 2000V AC for one minute between the input, output, and power terminals. This protects sensitive PLC/DCS equipment from high-voltage surges or ground loops on the AC line.
### B. Overload Resistance
The input circuit is designed to handle temporary surges (typically up to 20 times the rated current for 1 second), which is critical when monitoring motor starts.
### C. Frequency Response
It is designed to accurately process AC signals within the 40 Hz to 1 kHz range, making it suitable for both 50Hz and 60Hz power grids.
---
- ⤷