M2PE-13-R2/UL
AI

The **M2PE-13-R2/UL** is a specialized electronic component commonly used in industrial control systems and power distribution. It is primarily identified as a **Miniature Circuit Breaker (MCB)** or a **Supplementary Protector** manufactured by brands like Altech or similar industrial suppliers.
Below is a detailed breakdown of its electronic characteristics and specifications.
### 1. Technical Specifications
This component is designed to protect electrical circuits from overcurrents (overloads and short circuits).
| Feature | Specification |
| :--- | :--- |
| **Number of Poles** | 2-Pole (DP) |
| **Rated Current ($I_n$)** | 13 Amperes |
| **Voltage Rating** | 277V AC (Single Pole) / 480Y/277V AC (Multi-pole) |
| **Trip Curve** | Type E (High Inrush/Magnetic Trip) |
| **Interrupt Capacity** | 10kA |
| **Mounting Type** | DIN Rail (35mm) |
| **Standard/Safety** | UL 1077 Recognized |
---
### 2. Key Electronic Features
#### A. Trip Curve (Type E)
The "E" designation in the part number refers to the specific trip characteristic.
* **Thermal Trip:** Protects against long-term overloads.
* **Magnetic Trip:** Protects against short circuits. Type E curves are typically designed for circuits with high inductive loads or specific industrial motor applications where high startup surges are expected.
#### B. UL 1077 Compliance
Unlike UL 489 breakers (which are "Branch Circuit Protectors"), the **UL 1077** rating classifies this as a **Supplementary Protector**. This means:
* It is intended for use inside equipment (like PLCs, power supplies, or control panels).
* It provides additional protection where branch circuit protection is already provided or not required.
#### C. Two-Pole Configuration
The "2" in the suffix usually denotes a two-pole configuration. This allows the device to disconnect both the Line and Neutral (or two phases) simultaneously, ensuring the entire downstream circuit is isolated during a fault.
---
### 3. Application Use Cases
* **Industrial Automation:** Protecting PLC (Programmable Logic Controller) I/O modules.
* **Power Supplies:** Serving as an input/output fuse replacement for sensitive power converters.
* **Control Transformers:** Protecting the secondary side of industrial transformers.
* **Semiconductor Equipment:** Often used in cleanroom machinery due to its compact DIN rail footprint.
---
### 4. Wiring and Installation
```mermaid
graph LR
Line_In1[Phase 1] --> Terminal1[Breaker Pole 1]
Line_In2[Phase 2/N] --> Terminal2[Breaker Pole 2]
Terminal1 --> Load1[Device L1]
Terminal2 --> Load2[Device L2/N]
```
The device utilizes **pressure plate terminals**, allowing for secure connection of stranded or solid copper wires (typically 18-4 AWG depending on the specific frame).
- ⤷
What is the difference between UL 1077 and UL 489 ratings for this device?
- ⤷ How does the 'Type E' trip curve compare to the standard 'Type C' curve?
- ⤷ Can this breaker be used for DC voltage applications?