M2RTS-S-4D-R
AI

The **M2RTS-S-4D-R** is a specific model of an **RTD (Resistance Temperature Detector) Transmitter** manufactured by **M-System**. It is part of the M2 series, known for its "plug-in" design and high reliability in industrial signal conditioning.
---
### 1. Key Technical Specifications
Below is a breakdown of the electronic characteristics and capabilities of this specific model:
| Feature | Specification Details |
| :--- | :--- |
| **Input Type** | RTD (Pt 100, JPt 100, etc.) |
| **Output Type** | 4 to 20 mA DC (Direct Current) |
| **Power Input** | 24V DC |
| **Response Time** | ≤ 0.5 seconds (0 – 90%) |
| **Accuracy** | ±0.1% of span |
| **Isolation** | 3-way isolation (Input to Output to Power) |
| **Construction** | Plug-in base socket mount |
---
### 2. Functional Components
The "4D-R" suffix in the model name defines its specific electronic configuration:
* **Input (S):** Standard RTD input. It typically supports 3-wire connections to compensate for lead-wire resistance.
* **Output (4):** Represents a **4 to 20 mA DC** output signal, which is the industry standard for long-distance transmission with low noise interference.
* **Power (D):** Indicates the device operates on **24V DC** power supply.
* **Option (R):** Usually refers to the specific compliance or mounting orientation (Standard rack/base mounting).
---
### 3. Electronic Design Features
#### A. Linearization Circuitry
RTD elements do not have a perfectly linear resistance-to-temperature relationship. The M2RTS contains an internal microprocessor or analog linearization circuit that converts the non-linear resistance into a linear 4-20mA signal proportional to the temperature.
#### B. 3-Way Isolation
This is a critical electronic safety feature. The **Input**, **Output**, and **Power** circuits are electrically isolated from one another. This prevents:
* **Ground Loops:** Noise caused by different ground potentials.
* **Surge Propagation:** Protecting the PLC/DCS if a high-voltage surge hits the field sensor.
#### C. Burnout Protection
The device features "Upscale" or "Downscale" burnout protection. If the RTD wire breaks, the transmitter will force the output to a specific level (e.g., >20mA) to alert the control system of a hardware failure.
---
### 4. Wiring Diagram Concept
| Terminal | Function |
| :--- | :--- |
| **1 - 3** | RTD Sensor Input (A, B, b) |
| **4 - 5** | 4-20mA Output (+) and (-) |
| **7 - 8** | 24V DC Power Supply |
---
- ⤷
How do I calibrate the zero and span on the M2RTS-S-4D-R?
- ⤷ What is the maximum allowable loop resistance for the 4-20mA output?
- ⤷ Can this model be used with 2-wire or 4-wire RTDs?