The **M2UDS-FW3-R2** is a specific electronic component within the **M2UDS series**, primarily manufactured by **M-System (now MG CO., LTD.)**. This device is a **Rotary Motion Universal Digital Alarm**, typically used in industrial automation and process control to monitor frequency or rotation speeds.
---
### 1. Key Technical Specifications
The model code `M2UDS-FW3-R2` breaks down into specific hardware configurations:
| Feature | Specification | Description |
|:---|:---|:---|
| **Model Series** | M2UDS | Universal Digital Alarm (Plug-in) |
| **Input Type** | Frequency | Pulse signals from sensors (Proximity, Photoelectric, etc.) |
| **Input Range** | 0.001 Hz to 100 kHz | Highly sensitive frequency detection |
| **Output Type** | Relay Contact | 2-point SPDT relay outputs (Alarm 1 & Alarm 2) |
| **Power Supply** | 24V DC | Indicated by the "R2" suffix |
---
### 2. Core Electronic Functions
The device operates as a signal conditioner with threshold logic. Here is the electronic breakdown:
* **Pulse Processing:** It accepts pulse inputs (open collector, voltage pulses, or dry contacts) and converts the time interval between pulses into a digital value.
* **Dual Alarms:** It features two independent relay outputs. You can program these as "High" or "Low" alarms via the front-panel buttons.
* **Isolation:** It provides 3-way isolation (Input to Output to Power). This protects the control system from electrical surges or ground loops.
* **Digital Display:** The 4-digit LED display shows the current process value (e.g., RPM, Hz, or m/min) and is used for parameter configuration.
---
### 3. Connection Terminals
The unit typically uses a **M3 screw terminal** base. Below is a general overview of the pin-out logic:
| Terminal | Function |
|:---|:---|
| **1 - 2** | Power Input (24V DC) |
| **3 - 4** | Input Signal (Pulse/Frequency) |
| **5 - 6 - 7** | Relay Output 1 (NC - COM - NO) |
| **8 - 9 - 10** | Relay Output 2 (NC - COM - NO) |
---
### 4. Common Applications
* **Speed Monitoring:** Monitoring the RPM of a motor or conveyor belt.
* **Flow Calculation:** Taking pulses from a flow meter to trigger an alarm if the flow rate is too high/low.
* **Safety Interlocks:** Shutting down machinery if a rotational part stops unexpectedly.
- ⤷