M2VF-60-R2/CE
AI

The **M2VF-60-R2/CE** is a high-precision, ultra-slim signal conditioner (transducer) manufactured by **M-System**. It is specifically designed to convert a DC input signal into two isolated DC output signals.
Below is a detailed breakdown of its electronic specifications and technical characteristics.
---
### 1. General Specifications
| Feature | Specification |
| :--- | :--- |
| **Model Type** | M2VF (Ultra-slim Signal Conditioner) |
| **Input Signal** | 0 – 10V DC (Standard configuration for -60 model) |
| **Output 1** | 4 – 20mA DC |
| **Output 2** | 1 – 5V DC (Typical for R2 configuration) |
| **Power Input** | 24V DC (Indicated by 'R' in the code) |
| **Isolation** | 3-way isolation (Input to Output to Power) |
| **Standards** | CE Marking compliant |
---
### 2. Key Electronic Components & Design
The device is built using a combination of analog and digital processing components to ensure signal integrity:
* **Input Stage:** Features a high-impedance operational amplifier circuit to prevent loading effects on the source sensor.
* **Isolation Barrier:** Uses an internal **transformer-coupled isolation** method. This protects the control system from surges and eliminates ground loops between the field and the PLC.
* **Power Circuitry:** Designed for low power consumption (approx. 0.8W). It includes reverse polarity protection for the 24V DC supply.
* **Calibration Adjustments:** The front panel contains multi-turn potentiometers for **Zero** and **Span** adjustments, allowing the user to fine-tune the output accuracy (±10% range).
---
### 3. Connection Diagram (Internal Logic)
The following table represents the typical terminal mapping for the M2-series base:
| Terminal No. | Function | Description |
| :--- | :--- | :--- |
| **1** | Output 1 (+) | Positive 4-20mA Signal |
| **2** | Output 1 (-) | Negative 4-20mA Signal |
| **3** | Output 2 (+) | Positive 1-5V Signal |
| **4** | Output 2 (-) | Negative 1-5V Signal |
| **5** | Input (+) | Positive DC Input |
| **6** | Input (-) | Negative DC Input |
| **7** | Power (+) | 24V DC Positive |
| **8** | Power (-) | 24V DC Negative |
---
### 4. Technical Performance
* **Accuracy:** ±0.1% of span.
* **Temperature Coefficient:** ±0.015% per degree Celsius.
* **Response Time:** $\leq$ 0.5 seconds (0 – 90%).
* **Dielectric Strength:** 2000V AC @ 1 minute (Input to output to power to ground).
* **Mounting:** DIN rail mounting with a slim 5.9mm profile for high-density installation.
- ⤷
What are the specific wiring requirements for the 24V DC power supply?
- ⤷ How do I perform Zero and Span calibration on this specific model?
- ⤷ Can this unit be used with a 2-wire transmitter input?