M2VF-6FW-R
AI

The **M2VF-6FW-R** is a specific model of an **Electronic Transducer (Signal Conditioner)** manufactured by **M-System**. Its primary function is to convert a variable frequency input signal into a standard DC output signal (Voltage or Current).
Below is a breakdown of its electronic specifications and features.
---
### 1. Model Code Breakdown
The model name follows a specific nomenclature that defines its hardware capabilities:
| Code Segment | Meaning | Specification |
| :--- | :--- | :--- |
| **M2VF** | Series Name | Frequency Transducer (M2-Series) |
| **6** | Power Input | 100 – 240V AC |
| **FW** | Input Type | Variable Frequency (Dry contact or Voltage pulse) |
| **R** | Output Type | 4 – 20mA DC (Current Output) |
---
### 2. Key Electronic Specifications
The internal circuitry is designed for high precision and industrial-grade isolation.
* **Input Frequency Range:** User-definable, typically ranging from 0 – 0.01 Hz up to 0 – 10 kHz.
* **Output Signal:** 4 to 20 mA DC (Load resistance up to 750 $\Omega$).
* **Accuracy:** $\pm$0.1% of span.
* **Response Time:** Approx. 2 seconds (0 to 90%).
* **Isolation:** 3-way isolation (Input to Output to Power).
* **Dielectric Strength:** 2000V AC @ 1 minute.
---
### 3. Circuit Components and Design
The device consists of several critical stages of electronic processing:
#### A. Input Pulse Shaper
The input terminal accepts various pulse types (Open collector, Mechanical contact, or Voltage pulses). It includes a **comparator circuit** to square the incoming waves and filter noise.
#### B. Frequency-to-Voltage (F/V) Converter
The heart of the unit is a microcontroller-based or precision analog F/V converter. It counts the incoming pulses over a specific time window and generates a proportional internal reference voltage.
#### C. Isolation Barrier
To protect sensitive PLCs or Scada systems from field surges, it uses an **Optical Isolator** or **Transformer Isolation**. This ensures that electrical noise on the input side does not damage the output side.
#### D. Output Driver
The final stage converts the processed signal into a stable **4-20mA current loop**. It uses an operational amplifier with negative feedback to ensure the current remains constant regardless of the load resistance variations.
---
### 4. Terminal Wiring Diagram (Typical)
| Terminal No. | Function | Description |
| :--- | :--- | :--- |
| **1 - 2** | Power | 100-240V AC Supply |
| **3 - 4** | Input | Frequency Pulse (+ / -) |
| **5 - 6** | Output | 4-20mA DC Signal |
---
- ⤷