MDL-3/8-R
AI

The **MDL-3/8-R** is a specific type of electronic component known as a **Time-Delay Glass Tube Fuse**. It is manufactured by Eaton (formerly Bussmann) and is part of the MDL series, which is a standard for small-dimension electronic fuses.
---
## 1. Technical Specifications
Below are the core electronic parameters for the MDL-3/8-R:
| Parameter | Specification |
| :--- | :--- |
| **Current Rating** | 0.375A (3/8 Amp) |
| **Voltage Rating (AC)** | 250 VAC |
| **Fuse Type** | Time-Delay (Slow-Blow) |
| **Material** | Glass Tube with Nickel-plated Brass Endcaps |
| **Dimensions** | 1/4" x 1-1/4" (6.3mm x 32mm) |
| **Interrupting Rating** | 35A @ 250Vac / 10,000A @ 125Vac |
| **RoHS Compliant** | Yes (Indicated by the "-R" suffix) |
---
## 2. Key Characteristics
### A. Time-Delay Functionality
Unlike "Fast-Acting" fuses, the MDL-3/8-R is a **Slow-Blow** fuse. It is designed to withstand temporary surges or "inrush currents" that occur when a device (like a motor or a transformer) first turns on. It will only blow if the overcurrent persists, preventing nuisance tripping.
### B. The "-R" Suffix
In the part numbering system for Eaton/Bussmann, the **-R** stands for **RoHS compliance**. This means the part is manufactured without lead or other hazardous substances restricted by European Union standards.
### C. Construction
* **Visual Inspection:** Being a glass tube fuse, it allows for easy visual verification to see if the internal element has melted/broken.
* **Standard Sizing:** The 1/4" x 1-1/4" size is the "American Standard" size for many consumer electronics and industrial control panels.
---
## 3. Typical Applications
The MDL-3/8-R is generally used in low-current circuits that require protection against sustained overloads but have high initial power spikes:
* **Power Supplies:** Protecting the primary or secondary side of small transformers.
* **Control Circuits:** Industrial relay logic or small solenoid valves.
* **Consumer Electronics:** Older audio equipment, amplifiers, and appliances.
---
## 4. Part Number Breakdown
```text
MDL - 3/8 - R
| | |
| | +-- RoHS Compliant
| +-------- Current Rating (0.375 Amps)
+-------------- Series Name (Time-Delay Glass Fuse)
```
- ⤷
What is the difference between an MDL fuse and an AGC fuse?
- ⤷ Can I use a 250V fuse in a 125V circuit?
- ⤷ How do I test if an MDL-3/8-R fuse is blown using a multimeter?