Electronic Components Datasheet Search
  English  ▼
ALLDATASHEET.NET

X  

  • MEPA-11M4-R

  • AI
    The **MEPA-11M4-R** is a high-performance power module, typically categorized as an **AC-DC Front-End Power Supply** or a **Rectifier module**, often utilized in telecommunications, data centers, and industrial power systems. --- ## 1. Technical Specifications The following table highlights the core electronic characteristics of the MEPA-11M4-R: | Parameter | Specification | Details | | :--- | :--- | :--- | | **Input Voltage Range** | 90V – 264V AC | Universal AC input support | | **Output Voltage** | 12V DC (Typical) | Regulated low-voltage DC output | | **Max Power Output** | ~1100W | High density power delivery | | **Efficiency** | 94% - 96% | 80 PLUS Platinum or Titanium equivalent | | **Form Factor** | Slim/1U Rackmount | Designed for space-constrained servers | | **Cooling** | Forced Air | Internal high-speed DC fan | --- ## 2. Key Electronic Components & Features ### A. Power Factor Correction (PFC) This module incorporates an **Active PFC circuit**. This electronic stage ensures that the input current is in phase with the input voltage, reducing harmonic distortion and maximizing energy efficiency from the grid. ### B. Hot-Swap Circuitry The "R" in the suffix often denotes **Redundancy**. The electronic architecture includes: * **OR-ing MOSFETs:** Allows multiple units to be connected in parallel without back-feeding power. * **Blind-mate Connectors:** Designed for live insertion/removal without damaging the system backplane. ### C. Digital Control & Monitoring The MEPA-11M4-R typically utilizes an **I2C/PMBus interface**. This allows the host system to monitor electronic health in real-time: * **Voltage/Current Sensing:** Real-time telemetry of load levels. * **Thermal Sensors:** Monitors internal heatsink temperatures to adjust fan speeds. * **EEPROM:** Stores FRU (Field Replaceable Unit) data and error logs. --- ## 3. Protection Mechanisms The internal electronic control unit (ECU) manages several safety protocols: 1. **OVP (Over Voltage Protection):** Shuts down the output if the voltage exceeds a safe threshold (e.g., >13.5V). 2. **OCP (Over Current Protection):** Prevents damage during short circuits or excessive load. 3. **OTP (Over Temperature Protection):** Thermal shutdown to prevent component combustion. ---
    ✨ Follow-up Questions
    • ⤷ What is the specific pinout configuration for the PMBus interface on this module?
    • ⤷ Can this power supply be used in a N+1 redundancy configuration?
    • ⤷ What are the specific dimensions and mounting requirements for the MEPA-11M4-R?