MF-R110-0-99
AI

The **MF-R110-0-99** is a popular electronic component manufactured by **Bourns**. It belongs to the family of **Multifuse® Polymer PTC (Positive Temperature Coefficient)** resettable fuses.
---
## 1. Core Functionality
Unlike a traditional fuse that "blows" and must be replaced, the MF-R110 is **resettable**.
* **Normal State:** It has low resistance and allows current to flow.
* **Fault State:** If an overcurrent or overtemperature event occurs, the internal polymer heats up, causing its resistance to increase exponentially. This effectively "opens" the circuit.
* **Recovery:** Once the fault is removed and the device cools down, it returns to a low-resistance state.
---
## 2. Technical Specifications
The part number follows a specific nomenclature. Here are the key electrical characteristics for the **MF-R110**:
| Parameter | Value | Description |
| :--- | :--- | :--- |
| **$I_{hold}$** | 1.10 Amps | The maximum current the device will hold without tripping. |
| **$I_{trip}$** | 2.20 Amps | The minimum current at which the device is guaranteed to trip. |
| **$V_{max}$** | 60 Volts | The maximum voltage the device can withstand without damage. |
| **$I_{max}$** | 40 Amps | The maximum fault current the device can safely interrupt. |
| **$P_{d}$** | 1.5 Watts | Power dissipated when the device is in a tripped state. |
| **Resistance ($R_{min}/R_{1max}$)** | 0.15 - 0.38 $\Omega$ | The resistance range of the device at $23^\circ C$. |
---
## 3. Physical Attributes & Part Suffixes
The "-0-99" suffix provides specific details regarding the physical form and packaging:
* **MF-R:** Radial Leaded series.
* **110:** Represents the 1.10 Amp hold current rating.
* **-0:** Indicates that the leads are **straight** (un-kinked).
* **-99:** Indicates the packaging type (typically **bulk packaging**).
### Dimensions (Approximate)
* **Width:** ~13.0 mm
* **Height:** ~18.0 mm
* **Thickness:** ~3.0 mm
* **Lead Spacing:** ~5.1 mm
---
## 4. Common Applications
This component is typically used in circuits where overcurrent protection is needed but manual replacement of a fuse is difficult or undesirable:
1. **Industrial Controls:** Protecting PLCs and sensor loops.
2. **IEEE 1394 / USB Ports:** Protecting power rails from shorts.
3. **Security Systems:** Overload protection for sirens and sensors.
4. **Power Supplies:** Secondary side protection for transformers.
---