Electronic Components Datasheet Search
  English  ▼
ALLDATASHEET.NET

X  

  • MVS63T1CJ-R

  • AI
    The **MVS63T1CJ-R** is a specific technical part number, typically associated with high-performance electronic components used in power distribution and industrial automation. Specifically, this part belongs to the **Schneider Electric MasterPact MVS** series of Air Circuit Breakers (ACBs). --- ## 1. Core Specifications This component is designed to protect electrical systems from damage caused by overloads, short circuits, and equipment ground faults. | Specification | Details | | :--- | :--- | | **Product Series** | MasterPact MVS | | **Frame Size** | MVS08 to MVS40 (630A to 4000A) | | **Current Rating (In)** | 630 Amperes | | **Poles** | 3 Pole (3P) | | **Breaking Capacity (Icu)** | 50kA or 65kA at 415V (Standard for the "T" range) | | **Control Unit** | Integrated Trip Unit (ET) | | **Mounting Type** | Draw-out or Fixed (Depending on specific suffix) | --- ## 2. Key Electronic Features The electronic "intelligence" of the MVS63T1CJ-R is located in its **Micro-logic Trip Unit**. Unlike a simple fuse, these electronic parts provide precise control: ### A. Electronic Trip Unit (ET) * **Protection Functions:** It provides LSIG protection (Long time, Short time, Instantaneous, and Ground fault). * **True RMS Sensing:** The electronics measure the heat produced by the current, ensuring accurate tripping even in the presence of harmonics. ### B. Auxiliary Switches and Sensors * **O/F Contacts:** Electronic signaling contacts that indicate if the breaker is Open or Closed. * **SDE Contacts:** Fault-trip indication contacts that alert a remote monitoring system if the breaker tripped due to an electrical fault. * **Current Transformers (CTs):** Internal sensors that step down the high current into a low-level signal for the electronic processor. --- ## 3. Component Breakdown (Internal) | Component | Function | | :--- | :--- | | **Arc Chutes** | Dissipates the heat and energy when the contacts open under load. | | **Main Contacts** | High-conductivity silver alloy plates that carry the 630A load. | | **Charging Motor** | (Optional) Allows the breaker's spring mechanism to be charged remotely via an electrical signal. | | **Shunt Trip (MX)** | An electronic coil that allows the breaker to be tripped remotely by a PLC or emergency stop. | --- ## 4. Application Areas Because of its high current rating and electronic precision, the MVS63T1CJ-R is used in: * **Main Low Voltage Distribution Boards (MLVDB)**. * **Industrial Plants:** Protecting heavy machinery and motors. * **Commercial Buildings:** Powering HVAC systems and large lighting grids. * **Data Centers:** Where high reliability and fast trip times are required to protect servers.
    ✨ Follow-up Questions
    • ⤷ What is the difference between the 3-pole and 4-pole versions of this breaker?
    • ⤷ How do you calibrate the trip settings on the Micro-logic unit?
    • ⤷ Can this breaker be integrated into a Modbus or Ethernet communication network?