PDU-BP3R-R/Q
AI

The **PDU-BP3R-R/Q** is a high-performance Power Distribution Unit (PDU) typically used in server racks, data centers, and industrial computing environments. It is designed for redundancy and "bypass" capabilities, allowing maintenance on a UPS (Uninterruptible Power Supply) without shutting down the connected load.
---
### Key Electronic Components and Specifications
The electronic architecture of this unit focuses on power routing, surge protection, and circuit management.
| Component Category | Details & Specifications |
| :--- | :--- |
| **Input Power Interface** | Typically supports 100-240V AC; uses industrial-grade terminal blocks or high-amp plugs (like NEMA L6-30P or IEC 60309). |
| **Bypass Switch** | A manual rotary or toggle switch that electronically reroutes current from the UPS output directly to the Utility line. |
| **Circuit Breakers** | Equipped with electromagnetic or thermal-magnetic breakers (often 20A or 30A) for overcurrent protection. |
| **Output Receptacles** | A combination of IEC C13 (10A) and IEC C19 (16A/20A) outlets to power diverse server hardware. |
| **LED Indicators** | Visual electronic indicators for "Utility Power Available," "UPS Power Available," and "Bypass Mode Active." |
---
### Functional Electronic Features
#### 1. Dual-Path Logic
The unit contains internal copper busbars and high-capacity relays designed to handle "Make-Before-Break" transitions. This ensures that when switching from UPS power to Utility power (Bypass), there is no millisecond drop in voltage that would cause a server to reboot.
#### 2. Surge Suppression & Filtering
Integrated Metal Oxide Varistors (MOVs) are often included to protect downstream equipment from voltage spikes and electromagnetic interference (EMI) that might originate from the utility grid.
#### 3. Maintenance Bypass System (MBS)
The "BP" in the model name stands for **Bypass**. The electronic circuitry allows for:
* **Normal Mode:** Utility $\rightarrow$ UPS $\rightarrow$ PDU $\rightarrow$ Servers.
* **Bypass Mode:** Utility $\rightarrow$ PDU $\rightarrow$ Servers (allowing the UPS to be disconnected/replaced).
---
### Technical Schematic Overview
```mermaid
graph LR
A[Utility Power] --> B{Bypass Switch}
C[UPS Unit] --> B
B --> D[Circuit Breakers]
D --> E[Output Outlets C13/C19]
D --> F[Status LEDs]
```
---
- ⤷
What is the difference between the R and Q variants of this PDU?
- ⤷ Does this model support remote monitoring via SNMP?
- ⤷ What is the maximum amperage load for the PDU-BP3R series?