PJA100F-12-R
AI

The **PJA100F-12-R** is an AC-DC enclosed switch-mode power supply manufactured by **Cosel**. It is designed for industrial applications requiring high reliability and a compact form factor.
---
## 1. Technical Specifications
The following table outlines the core electronic parameters of the PJA100F-12-R:
| Parameter | Specification | Details |
| :--- | :--- | :--- |
| **Output Voltage** | 12V DC | Adjustable via built-in potentiometer (10.8V - 13.2V) |
| **Output Current** | 8.4A | Maximum continuous current |
| **Power Rating** | 100.8W | Total output capacity |
| **Input Voltage** | 85V - 264V AC | Universal input (also supports 120V - 370V DC) |
| **Efficiency** | 85% - 87% | Depending on input voltage and load |
| **Suffix "-R"** | Remote Control | Includes remote ON/OFF logic capability |
---
## 2. Key Electronic Components & Features
### A. Power Factor Correction (PFC)
The PJA series includes **Active PFC** circuitry. This reduces harmonic distortion and ensures compliance with international standards like IEC61000-3-2. This is critical for industrial environments to prevent electrical noise from feeding back into the grid.
### B. Remote ON/OFF (The "-R" Suffix)
The "R" in the model name indicates the inclusion of a dedicated remote control circuit.
* **Mechanism:** Allows the power supply output to be toggled using an external signal without cutting the AC mains.
* **Benefit:** Reduces wear on mechanical switches and allows for automated power sequencing via a PLC or microcontroller.
### C. Protection Circuits
The unit integrates three primary protection mechanisms:
1. **Overcurrent Protection (OCP):** Automatically recovers when the fault condition is removed.
2. **Overvoltage Protection (OVP):** Shuts down the unit if the output exceeds approximately 115% of the rated voltage.
3. **Thermal Protection:** Safeguards against overheating due to poor ventilation or overloading.
---
## 3. Physical Layout & Mounting
The PJA100F uses a high-density design to minimize its footprint.
* **Cooling:** Convection cooled (no internal fan required), which increases the Mean Time Between Failures (MTBF) and ensures silent operation.
* **Terminals:** M3.5 screw terminals for secure industrial wiring.
* **EMI Filter:** Integrated EMI/EMC filtering to meet Class B emission standards.
---
## 4. Usage Considerations
If you are integrating this into a PCB or system, note the following:
* **Derating:** The output current must be derated if the ambient temperature exceeds 50°C.
* **Isolation:** The unit provides 3,000V AC isolation between input and output, ensuring safety for downstream low-voltage electronics.
- ⤷
How does the Remote ON/OFF logic (R suffix) specifically trigger the power state?
- ⤷ What are the specific mounting orientations recommended for optimal convection cooling?
- ⤷ Does this model support parallel operation for higher current requirements?