R7FN-DA16-R/Q
AI

The **R7FN-DA16-R/Q** is a specific model within the **OMRON DeviceNet Remote I/O** terminal series. It is designed to bridge the gap between a DeviceNet master controller (like a PLC) and field devices, providing 16 digital input points.
---
## Technical Specifications
The following table highlights the core electronic characteristics of the unit:
| Feature | Specification |
| :--- | :--- |
| **I/O Points** | 16 Digital Inputs |
| **Input Type** | NPN/PNP (Multi-vendor support) |
| **Communication Protocol** | DeviceNet |
| **Power Supply Voltage** | 24 VDC (via DeviceNet cable) |
| **I/O Connection** | Removable Screw Terminal Block |
| **Mounting** | DIN Rail or Surface Mount |
| **Weight** | Approx. 150g |
---
## Electronic Components & Architecture
### 1. DeviceNet Interface
The unit contains a transceiver chip and an internal controller that manages the CAN-based **DeviceNet** protocol. This allows the 16 inputs to be mapped directly into the PLC's memory over a single network cable, reducing wiring complexity.
### 2. Digital Input Circuitry
The inputs are typically **Current-Sinking (NPN)** or **Current-Sourcing (PNP)**.
* **Optocouplers:** The inputs are internally isolated using optoisolators to protect the internal logic from high-voltage spikes or noise on the field side.
* **Input Impedance:** Designed to match standard 24V sensors (Proximity, Limit Switches, etc.).
### 3. Indicator LEDs
The front panel contains diagnostic LEDs used for troubleshooting:
* **MS (Module Status):** Indicates if the hardware is operating correctly.
* **NS (Network Status):** Indicates the state of the DeviceNet connection.
* **I/O Indicators:** 16 yellow LEDs showing the ON/OFF state of each individual input.
---
## Wiring Logic
The "R/Q" suffix generally refers to the specific terminal layout or connector type. For the R7FN series, wiring is typically handled as follows:
```yaml
Terminal Layout:
[V+] -> DeviceNet Power (+)
[CAN_H] -> Data High
[Shield] -> Grounding
[CAN_L] -> Data Low
[V-] -> DeviceNet Power (-)
Input Terminals:
[00] to [15] -> Signal Inputs
[COM] -> Common reference point
```
---
## Key Advantages
* **Compact Form Factor:** Saves space in control cabinets.
* **Removable Terminals:** Allows for unit replacement without rewiring each individual sensor.
* **Baud Rate Auto-Detection:** Automatically synchronizes with the network speed (125k, 250k, or 500k bps).
- ⤷