RAC48-24SSLASHOF
AI

The **RAC48-24S/SASH/OF** is a specialized, open-frame AC/DC converter manufactured by **RECOM Power**. This specific model is designed for high-reliability industrial and medical applications where space is limited and high efficiency is required.
Below is a breakdown of its electronic specifications and features.
---
### 1. Key Technical Specifications
| Parameter | Specification |
| :--- | :--- |
| **Input Voltage Range** | 85V AC to 264V AC (Universal Input) |
| **Output Voltage** | 24V DC |
| **Output Power** | 48 Watts |
| **Output Current** | 2.0 Amps |
| **Efficiency** | ~88% Typical |
| **Isolation Voltage** | 4kV AC (Input to Output) |
| **Form Factor** | Open Frame (/OF suffix) |
---
### 2. Breakdown of the Model Name
Understanding the nomenclature helps identify the part's capabilities:
* **RAC48:** Series name, indicating a 48W rated AC/DC converter.
* **24S:** Indicates a Single (S) output of 24 Volts.
* **SASH:** This suffix usually refers to the specific safety certification tier or a specific physical mounting/terminal style (often related to enhanced surge protection or medical grade).
* **OF:** Stands for **Open Frame**. This means the PCB is exposed (no plastic or metal casing), allowing for better heat dissipation via airflow and a smaller footprint.
---
### 3. Electronic Protection Features
The internal circuitry includes several protection layers to prevent damage to the load or the power supply itself:
1. **Over-Voltage Protection (OVP):** Clamps the output if the voltage exceeds a safe threshold.
2. **Short Circuit Protection (SCP):** The unit will enter "hiccup mode" or shut down if a short is detected, recovering automatically once the fault is removed.
3. **Over-Load Protection (OLP):** Prevents the internal components from overheating if the current draw exceeds 2.0A.
4. **EMI Filtering:** Includes internal Class B EMC filtering components to minimize electromagnetic interference with nearby electronics.
---
### 4. Physical and Environmental Characteristics
* **Cooling:** Primarily relies on free-air convection. Because it is an **Open Frame** design, it is crucial to maintain adequate clearance around the board.
* **Operating Temperature:** Generally rated from -25°C to +70°C (with derating at higher temperatures).
* **Connectors:** Typically utilizes pin-headers or screw terminals depending on the specific sub-variation of the SASH line.
---
- ⤷
What are the specific safety certifications (Medical vs Industrial) for the SASH variant?
- ⤷ How much derating is required for this part when operating above 50\u00b0C?
- ⤷ What is the physical footprint/dimensions of the RAC48 open frame series?