The **REBS-6Z-R** is an electronic relay base primarily used in fire alarm and security systems. It is designed to interface between a standard detector and a control panel, providing a relay output for external device triggering.
### 1. Technical Specifications
Below is a summary of the core electrical and mechanical characteristics of the REBS-6Z-R:
| Feature | Specification |
| :--- | :--- |
| **Operating Voltage** | 15 – 30 VDC |
| **Quiescent Current** | < 50 µA (typical) |
| **Relay Contact Rating** | 1A @ 30VDC / 0.5A @ 125VAC |
| **Contact Type** | Form C (Single Pole Double Throw - SPDT) |
| **Operating Temperature** | -10°C to +50°C |
| **Compatibility** | 6-inch detector heads (conventional systems) |
---
### 2. Key Electronic Components & Functionality
The unit functions as an interface module. Its electronic architecture focuses on switching power based on the detector’s status.
* **Relay Coil (Electromagnetic):** The heart of the base. When the fire detector senses smoke/heat, it completes a circuit that energizes the internal coil, switching the mechanical contacts.
* **Terminal Blocks:** Robust screw terminals designed to accommodate wire sizes between 14-22 AWG. These provide the physical connection points for Zone In/Out and Relay NC/NO/COM.
* **Blocking Diode (Optional/Context Dependent):** Some versions include a diode to prevent reverse polarity damage or to assist in circuit monitoring.
* **Base Contacts:** Spring-loaded metal plates that ensure a high-conductivity connection between the plug-in detector head and the base electronics.
---
### 3. Connection Pinout
The internal wiring follows a standardized logic to ensure the relay triggers simultaneously with the detector head.
1. **Terminals 1 & 2:** Zone positive (+) and negative (-) input.
2. **Terminal 3:** Remote indicator output (for external LEDs).
3. **Terminals 4, 5, & 6:** The Relay outputs:
* **Common (COM)**
* **Normally Open (NO)**
* **Normally Closed (NC)**
---
### 4. Typical Applications
The relay functionality is typically used to automate building responses during an alarm event:
* **HVAC Shutdown:** Turning off fans to prevent smoke spread.
* **Elevator Recall:** Sending elevators to the ground floor.
* **Door Release:** Releasing magnetic door holders.
* **Access Control:** Unlocking turnstiles or emergency exits.
---
- ⤷