Electronic Components Datasheet Search
  English  ▼
ALLDATASHEET.NET

X  

  • RWS1000B-36-R

  • AI
    ### Technical Overview: TDK-Lambda RWS1000B-36-R The **RWS1000B-36-R** is a high-performance, industrial-grade AC-DC power supply manufactured by TDK-Lambda. It is part of the RWS-B series, designed for high reliability and long-term stability in industrial applications. --- ### 1. Key Technical Specifications The following table highlights the primary electrical characteristics of this specific model: | Parameter | Specification | | :--- | :--- | | **Output Voltage** | 36V DC | | **Output Current** | 28A | | **Max Output Power** | 1008W | | **Input Voltage Range** | 85 - 265V AC (Universal) | | **Efficiency** | ~88% at 230VAC | | **Cooling** | Internal Fan (Forced Air) | | **Mounting Type** | Chassis Mount (Enclosed) | --- ### 2. Core Electronic Components and Design Features The "R" suffix in the model number denotes specific remote control functionality. Below are the critical electronic aspects of the unit: #### A. Input Section * **Active PFC (Power Factor Correction):** Includes an active circuit to ensure compliance with EN61000-3-2 standards, reducing harmonic distortion and improving energy efficiency. * **EMI Filtering:** Integrated multi-stage filters to minimize electromagnetic interference, meeting Class B conducted emission standards. #### B. Control and Monitoring (The "-R" Suffix) * **Remote ON/OFF:** This specific model includes an external signal interface to turn the power supply output on or off without disconnecting the AC input. * **Remote Sensing:** Compensates for voltage drops across the load cables to ensure precise 36V delivery at the point of load. * **DC Good Signal:** An open-collector signal that monitors the output voltage status. #### C. Protection Circuitry * **Overvoltage Protection (OVP):** Shuts down the unit if the output exceeds approximately 115-140% of the rated voltage. * **Overcurrent Protection (OCP):** Constant current limiting with automatic recovery (hiccup or constant current mode depending on the load). * **Thermal Protection:** Internal sensors shut down the unit if the internal temperature exceeds safe operating limits due to fan failure or restricted airflow. --- ### 3. Physical Interface The unit uses heavy-duty screw terminals for high-current connections: * **AC Input:** L, N, and Ground terminals. * **DC Output:** Multiple "+" and "-" screw terminals to accommodate heavy-gauge wiring for 28A. * **Signal Connector:** A small pin-header for the Remote ON/OFF and Remote Sensing functions.
    ✨ Follow-up Questions
    • ⤷ What is the difference between the RWS1000B and the HWS series from TDK-Lambda?
    • ⤷ How do I wire the Remote ON/OFF circuit for this specific model?
    • ⤷ What are the derating curves for this power supply at high temperatures?