RWS1000B-36-R
AI

### Technical Overview: TDK-Lambda RWS1000B-36-R
The **RWS1000B-36-R** is a high-performance, industrial-grade AC-DC power supply manufactured by TDK-Lambda. It is part of the RWS-B series, designed for high reliability and long-term stability in industrial applications.
---
### 1. Key Technical Specifications
The following table highlights the primary electrical characteristics of this specific model:
| Parameter | Specification |
| :--- | :--- |
| **Output Voltage** | 36V DC |
| **Output Current** | 28A |
| **Max Output Power** | 1008W |
| **Input Voltage Range** | 85 - 265V AC (Universal) |
| **Efficiency** | ~88% at 230VAC |
| **Cooling** | Internal Fan (Forced Air) |
| **Mounting Type** | Chassis Mount (Enclosed) |
---
### 2. Core Electronic Components and Design Features
The "R" suffix in the model number denotes specific remote control functionality. Below are the critical electronic aspects of the unit:
#### A. Input Section
* **Active PFC (Power Factor Correction):** Includes an active circuit to ensure compliance with EN61000-3-2 standards, reducing harmonic distortion and improving energy efficiency.
* **EMI Filtering:** Integrated multi-stage filters to minimize electromagnetic interference, meeting Class B conducted emission standards.
#### B. Control and Monitoring (The "-R" Suffix)
* **Remote ON/OFF:** This specific model includes an external signal interface to turn the power supply output on or off without disconnecting the AC input.
* **Remote Sensing:** Compensates for voltage drops across the load cables to ensure precise 36V delivery at the point of load.
* **DC Good Signal:** An open-collector signal that monitors the output voltage status.
#### C. Protection Circuitry
* **Overvoltage Protection (OVP):** Shuts down the unit if the output exceeds approximately 115-140% of the rated voltage.
* **Overcurrent Protection (OCP):** Constant current limiting with automatic recovery (hiccup or constant current mode depending on the load).
* **Thermal Protection:** Internal sensors shut down the unit if the internal temperature exceeds safe operating limits due to fan failure or restricted airflow.
---
### 3. Physical Interface
The unit uses heavy-duty screw terminals for high-current connections:
* **AC Input:** L, N, and Ground terminals.
* **DC Output:** Multiple "+" and "-" screw terminals to accommodate heavy-gauge wiring for 28A.
* **Signal Connector:** A small pin-header for the Remote ON/OFF and Remote Sensing functions.
- ⤷
What is the difference between the RWS1000B and the HWS series from TDK-Lambda?
- ⤷ How do I wire the Remote ON/OFF circuit for this specific model?
- ⤷ What are the derating curves for this power supply at high temperatures?