SES-2A2-R/Q
AI

The **SES-2A2-R/Q** is a high-performance, differential pressure sensor (also classified as a pressure transmitter) typically used in industrial automation, HVAC systems, and cleanroom environments. It is part of the SES series designed for high precision in measuring low-pressure ranges.
---
### ## 1. Technical Specifications
The device converts physical pressure differences into standardized electrical signals. Below are the primary electronic and mechanical specifications:
| Feature | Specification |
| :--- | :--- |
| **Input Type** | Differential Pressure (Air and Neutral Gases) |
| **Supply Voltage** | 24V DC/AC (±15%) |
| **Output Signal (R)** | 4-20 mA (Current Loop) |
| **Output Signal (Q)** | 0-10 V DC (Voltage) |
| **Accuracy** | ±1.0% to ±1.5% FS (Full Scale) |
| **Response Time** | < 100ms (Adjustable in some sub-models) |
| **Protection Class** | IP65 (NEMA 4 equivalent) |
---
### ## 2. Core Electronic Components
The reliability of the SES-2A2-R/Q stems from several key internal stages:
1. **Piezoresistive Sensing Element:**
* The "heart" of the device. It uses a silicon-based micro-machined diaphragm with integrated strain gauges.
* When pressure is applied, the diaphragm deforms, changing the electrical resistance (the Piezoresistive effect).
2. **ASIC (Application-Specific Integrated Circuit):**
* This component handles **Signal Conditioning**.
* It amplifies the millivolt signal from the sensor and performs linear temperature compensation to ensure accuracy across various climates.
3. **Output Conversion Circuit:**
* **"R" Version:** Contains a V/I (Voltage to Current) converter to output a stable 4-20mA signal, ideal for long-distance transmission without signal loss.
* **"Q" Version:** Contains a voltage regulator to output a steady 0-10V signal for PLC or BMS integration.
4. **Protection Circuitry:**
* Includes **Reverse Polarity Protection** to prevent damage if the power wires are swapped.
* Includes **EMC Filtering** to suppress electromagnetic interference from nearby motors or heavy machinery.
---
### ## 3. Wiring Configuration
Most SES series units utilize a standard 3-wire or 2-wire terminal block depending on the output type.
```text
Terminal 1: +24V Supply (V+)
Terminal 2: Common / Ground (GND)
Terminal 3: Signal Output (Out)
```
---
### ## 4. Applications
* **Filter Monitoring:** Measuring the pressure drop across air filters to determine when they need replacement.
* **Cleanrooms:** Maintaining a positive pressure environment to keep contaminants out.
* **Fan Control:** Providing feedback to Variable Frequency Drives (VFDs) to maintain constant airflow.
- ⤷
What is the maximum pressure range supported by the SES-2A2 series?
- ⤷ How do I calibrate the zero-point on this specific sensor?
- ⤷ Can the SES-2A2-R be used for liquid pressure measurements?