The **VP3-0055-R** is a high-performance power inductor from the **Versa-Pac (VP)** series, manufactured by **Eaton (formerly Coiltronics/Bussmann)**. It is characterized by its multi-winding design, which offers extreme versatility in power circuit design.
---
### 1. Key Technical Specifications
The "0055" in the part number indicates the specific core size and winding configuration. Below are the primary electrical characteristics:
| Parameter | Value / Specification |
| :--- | :--- |
| **Inductance (Open Circuit)** | ~4.6 µH to 167 µH (Configuration dependent) |
| **Current Rating (Irms)** | ~0.7A to 5.4A (Configuration dependent) |
| **Number of Windings** | 6 Independent Windings |
| **DC Resistance (DCR)** | ~0.024 Ω per winding |
| **Isolation Voltage** | 500VAC (Winding to Winding) |
| **Operating Temperature** | -40°C to +125°C |
| **Package Type** | Surface Mount (SMD) |
---
### 2. Physical Construction & Design
The VP3-0055-R is unique because it contains **six identical, independent windings** on a single ferrite core. This "Versa-Pac" architecture allows engineers to connect the windings in various ways:
* **Series Connection:** Increases total inductance.
* **Parallel Connection:** Increases current carrying capacity.
* **Transformer Mode:** Can be used as a 1:1 or multi-tap transformer (Flyback, Forward, or SEPIC).
* **Inductor Mode:** Used for filtering or energy storage in DC-DC converters.
---
### 3. Applications
Due to its flexibility, this part is commonly found in:
* **DC-DC Converters:** Buck, Boost, and SEPIC topologies.
* **Isolation:** Providing low-power isolated rails.
* **Feedback Loops:** Used as a sensing or auxiliary winding.
* **Telecommunications:** Power supplies for networking equipment.
---
### 4. Part Number Breakdown
* **VP:** Versa-Pac Series.
* **3:** Size/Frame dimension (approx. 13mm x 13mm footprint).
* **0055:** Core and winding specific code.
* **-R:** RoHS compliant (Lead-free).
---
- ⤷