The **W2RS-0C2-R2/Q** is a high-precision, industrial-grade **Current Transducer (Signal Conditioner)** manufactured by **M-System** (now part of MG CO., LTD). It is primarily used to convert alternating current (AC) into a standardized DC signal for use in PLC, DCS, or monitoring systems.
---
## 1. Technical Specifications
The following table outlines the core electronic characteristics of the W2RS-0C2-R2/Q:
| Parameter | Specification | Details |
| :--- | :--- | :--- |
| **Model Type** | W2RS | Two-wire / Dual-output Signal Conditioner |
| **Input Signal** | 0 – 5A AC | Standard CT (Current Transformer) secondary input |
| **Output 1** | 4 – 20mA DC | Standard process control signal |
| **Output 2** | 4 – 20mA DC | Independent secondary output |
| **Power Supply** | 24V DC | Ripple 10% p-p max. |
| **Accuracy** | ±0.3% | Relative to the input span |
| **Response Time** | ≤ 0.5 sec | Time to reach 90% of final value |
| **Insulation Resistance** | 100 MΩ | Measured at 500V DC |
---
## 2. Component Features
The device is engineered for reliability in harsh electrical environments. Key electronic features include:
### A. RMS Sensing
Unlike basic rectifiers, this unit uses **True RMS** sensing. This allows it to accurately measure current even if the waveform is distorted by non-linear loads (like Variable Frequency Drives).
### B. Isolation Technology
The unit features **triple isolation**:
1. **Input to Output:** Protects sensitive PLC cards from high-voltage surges on the current line.
2. **Output to Output:** Ensures the two 4-20mA signals do not interfere with each other.
3. **Power to Ground:** Prevents ground loops.
### C. Construction & Mounting
* **Housing:** Flame-resistant resin (Black).
* **Terminal Blocks:** M3.5 screw terminals (nickel-plated steel).
* **Mounting:** Standard DIN rail or wall mounting.
---
## 3. Wiring Configuration
The `/Q` suffix usually indicates a specific factory setting or a specialized option (like conformal coating or specific labeling). Below is a typical wiring logic for the W2RS series:
```text
Input (AC) Output 1 (DC) Output 2 (DC)
[1] --- (+) [5] --- (+) [7] --- (+)
[2] --- (-) [6] --- (-) [8] --- (-)
Power Supply (24V DC)
[9] --- (+)
[10] -- (-)
```
---
## 4. Application Use Case
This part is typically used in **Power Distribution Centers**:
* **Monitoring:** Taking a 5A signal from a large Current Transformer (CT) installed on a high-voltage busbar.
* **Redundancy:** Providing one 4-20mA signal to a local digital display and a second 4-20mA signal to a remote SCADA system simultaneously.
- ⤷
What is the significance of the '/Q' suffix in M-System part numbers?
- ⤷ Can this transducer handle a 1A AC input instead of 5A?
- ⤷ How does True RMS sensing differ from mean-value sensing in this device?