AI

The **W2SP-2BB-R/UL** is a high-performance, chassis-mount power entry module (PEM) typically used in industrial and medical applications. It integrates a power inlet, a switch, and a circuit breaker/fuse holder into a single compact unit.
---
### ## Technical Specifications Overview
The following table outlines the primary electrical and mechanical characteristics of the W2SP-2BB-R/UL:
| Characteristic | Specification |
| :--- | :--- |
| **Component Type** | Power Entry Module (PEM) |
| **Mounting Type** | Snap-in / Chassis Mount |
| **Inlet Type** | IEC 60320-1 C14 |
| **Voltage Rating** | 250V AC |
| **Current Rating** | 10A (UL/CSA), 10A (VDE) |
| **Switch Type** | 2-Pole Rocker Switch |
| **Circuit Protection** | Integrated Circuit Breaker |
| **Termination** | Quick Connect / Solder Tabs |
| **Safety Approvals** | UL, CSA, VDE, RoHS |
---
### ### Key Electronic Components
The unit is a "3-in-1" module designed to handle the input stage of an electronic device:
1. **IEC C14 Power Inlet:** The standard interface for a detachable power cord (common in PCs and lab equipment).
2. **Double-Pole Rocker Switch:** Unlike single-pole switches, a 2-pole switch disconnects both the "Live" and "Neutral" wires simultaneously, providing a higher level of safety during maintenance.
3. **Circuit Breaker (Thermal):** The "R" in the suffix often denotes a resettable thermal protector. Instead of replacing a fuse, the user can reset the breaker if an overcurrent event occurs.
4. **RFI/EMI Filter (Optional/Series specific):** While the W2SP series focuses on the switch/breaker combo, some variations include an internal LC filter to suppress electromagnetic interference.
### ### Typical Applications
* **Medical Equipment:** High reliability and double-pole switching are standard requirements for patient-side devices.
* **Industrial Automation:** Used in control panels where space is limited and protection is critical.
* **Laboratory Instrumentation:** Provides a clean power interface with easy-to-access reset functionality.
---
### ### Wiring Diagram Logic
Internally, the wiring follows this sequence:
1. **Input:** AC Line (L), Neutral (N), and Ground (G) enter via the C14 pins.
2. **Protection:** The Line and Neutral pass through the thermal circuit breaker.
3. **Switching:** The circuit is interrupted or completed by the 2-pole rocker switch.
4. **Output:** Power is delivered to the internal circuitry of the host device via the rear terminals.