W2TG0-2D1-R/N
AI

The **W2TG0-2D1-R/N** is a specific model identifier typically associated with **industrial AC cooling fans**, often manufactured by companies like **EBM-PAPST** or similar high-end thermal management firms. These fans are designed for heavy-duty applications like server racks, control cabinets, and medical equipment.
---
### 1. Technical Specifications Overview
Below is a breakdown of the typical electronic and mechanical characteristics for this series:
| Parameter | Specification |
| :--- | :--- |
| **Input Voltage** | 230V AC (Nominal) |
| **Frequency** | 50 / 60 Hz |
| **Bearing Type** | Dual Ball Bearing (for long life) |
| **Power Consumption** | Approx. 20W - 30W (Depending on load) |
| **Airflow Capacity** | ~90 - 110 CFM |
| **Speed (RPM)** | 2700 - 3000 RPM |
| **Housing Material** | Die-cast aluminum |
| **Connection Type** | Lead wires (R/N usually denotes Red/Neutral or specific wiring) |
---
### 2. Key Electronic Components
#### A. Shaded-Pole Motor
The internal motor is usually a **shaded-pole AC motor**.
- **Simple Design:** It uses a copper ring (shading coil) around part of each pole to create a rotating magnetic field.
- **Reliability:** It contains no brushes or complex electronic switching, making it highly resistant to electromagnetic interference (EMI).
#### B. Thermal Protection
Most fans in this series include an **Impedance Protection** or a **Thermal Cutoff**.
- **Impedance Protected:** The motor is designed so that if the rotor is locked (stalled), the heat generated by the windings will not exceed the insulation's temperature limit, preventing a fire without needing a separate fuse.
#### C. Dual Ball Bearing System
From an electromechanical standpoint, the use of ball bearings over sleeve bearings ensures:
- Lower friction at high temperatures.
- Horizontal or vertical mounting versatility.
- MTBF (Mean Time Between Failure) often exceeding 50,000 hours.
---
### 3. Wiring Configuration
The suffix **/N** often refers to the termination type or a specific electrical variant.
```markdown
L (Line) -----> [ Black/Brown Wire ]
N (Neutral) -----> [ Blue/White Wire ]
PE (Earth) -----> [ Green/Yellow Wire ]
```
---
### 4. Typical Applications
* **Enclosure Cooling:** Preventing heat buildup in PLC and electrical cabinets.
* **Networking Gear:** Cooling high-density server switches.
* **Industrial Power Supplies:** Active heat dissipation for large transformers or rectifiers.
- ⤷
What is the exact dimensions/frame size of the W2TG0 series?
- ⤷ How does impedance protection differ from thermal fuse protection in these fans?
- ⤷ Is there a DC equivalent model for lower power consumption applications?