W2TG0-4A4-R2
AI

The **W2TG0-4A4-R2** is a specific technical part number, typically associated with high-performance cooling solutions, specifically **AC Axial Fans** manufactured by companies like **eBM-papst**.
Below is a detailed breakdown of the electronic and mechanical specifications for this component.
---
### 1. Technical Specifications
The following table summarizes the core electronic and physical attributes of the W2TG0-4A4-R2:
| Feature | Specification |
| :--- | :--- |
| **Component Type** | AC Axial Fan |
| **Voltage Rating** | 115 VAC (Typical for this series) |
| **Frequency** | 50/60 Hz |
| **Power Consumption** | ~20 - 30 Watts |
| **Bearing Type** | Ball Bearing (Long life) |
| **Housing Material** | Die-cast aluminum |
| **Impeller Material** | Sheet steel / Plastic (depending on sub-batch) |
| **Termination** | Lead wires or Terminal lugs |
---
### 2. Key Electronic Features
#### A. Motor Construction
The unit uses a **Shaded Pole Motor** or a **Capacitor Motor** (depending on the exact revision). These motors are brushless, which reduces electromagnetic interference (EMI) and increases the lifespan of the electronic assembly.
#### B. Thermal Protection
* **Impedance Protection:** The motor windings are designed so that if the fan is stalled (locked rotor), the internal resistance prevents the temperature from rising high enough to cause a fire or melt the insulation.
* **Insulation Class:** Usually Class B or F, allowing it to operate in high-temperature environments (up to 70°C).
#### C. Power Management
Because it operates on alternating current (AC), it does not require an external DC driver. However, it is sensitive to frequency shifts; running a 60Hz rated fan on a 50Hz circuit will result in lower RPM and reduced cooling efficiency.
---
### 3. Application Use-Cases
This part is commonly found in industrial and telecommunications equipment due to its robustness:
1. **Server Racks:** High airflow to prevent CPU overheating.
2. **Power Supplies:** Heat dissipation for large-scale industrial PSUs.
3. **Control Cabinets:** Ensuring airflow through automated PLC enclosures.
---
### 4. Wiring Identification
*Typically, these units follow a standard color-coding or terminal marking:*
* **L (Line):** Connection to the hot wire.
* **N (Neutral):** Connection to the neutral wire.
* **PE (Ground):** Usually a screw terminal on the metal housing for safety grounding.
---
- ⤷
What is the maximum CFM (airflow) rating for the W2TG0-4A4-R2?
- ⤷ Are there DC-operated equivalents for this specific fan size?
- ⤷ How do I troubleshoot a fan that is drawing power but not spinning?