W2VS-2116-R
AI

The **W2VS-2116-R** is a specific model of a **Signal Conditioner / Signal Isolator** (typically part of the W2 series by manufacturers like M-System). These devices are used in industrial automation to convert, isolate, and transmit electrical signals between field sensors and control systems (PLC/DCS).
---
## 1. Technical Specifications Breakdown
The alphanumeric code "W2VS-2116-R" describes the specific internal electronic configuration:
| Feature | Specification | Description |
| :--- | :--- | :--- |
| **Model Series** | W2VS | Ultra-slim 2-wire signal conditioner / isolator. |
| **Input Signal** | **2** | 4 – 20 mA DC |
| **Output 1** | **1** | 4 – 20 mA DC |
| **Output 2** | **1** | 4 – 20 mA DC (Dual Output) |
| **Power Input** | **6** | 100 – 240V AC |
| **Compliance** | **R** | Standard RoHS / CE Compliance |
---
## 2. Key Electronic Components & Functionality
The internal circuitry of the W2VS-2116-R is designed to handle three primary tasks:
### A. Galvanic Isolation
* **Optoisolators:** The device uses optical coupling to transfer the signal from input to output without a physical electrical connection.
* **Purpose:** This prevents "Ground Loops" and protects sensitive PLC inputs from high-voltage surges or noise in the field wiring.
### B. Signal Conversion (Dual Output)
* **Operational Amplifiers (Op-Amps):** Precision amplifiers are used to split a single 4-20mA input into two independent 4-20mA outputs.
* **Precision Resistors:** Low-tolerance resistors ensure that the 1:1 ratio of input to output remains accurate (typically within ±0.1% span).
### C. Power Supply Section
* **AC/DC Rectifier:** Since the "6" code indicates an AC power supply, the unit contains a small internal transformer or switching power supply (SMPS) to convert 100-240V AC down to the internal DC operating voltage (usually 24V DC).
---
## 3. Terminal Configuration
The device typically utilizes a plug-in base or DIN-rail mounting system with the following electronic connection points:
| Terminal Type | Function |
| :--- | :--- |
| **Input (+ / -)** | Receives the 4-20mA loop from the field sensor. |
| **Output 1 (+ / -)** | Sends the first isolated 4-20mA signal to a controller. |
| **Output 2 (+ / -)** | Sends the second isolated 4-20mA signal to a display or recorder. |
| **Power (L / N)** | 100-240V AC mains power connection. |
---
## 4. Summary of Use Case
If you have a sensor (like a pressure transmitter) and you need to send that data to both a **PLC** and a **Local Chart Recorder** simultaneously without the two devices interfering with each other, the W2VS-2116-R acts as the electronic "bridge" and "shield" between them.
- ⤷
What is the maximum load resistance for the 4-20mA outputs on this model?
- ⤷ Does the W2VS-2116-R support HART signal pass-through?