Electronic Components Datasheet Search
  English  ▼
ALLDATASHEET.NET

X  

  • W5VS-AB1-R2

  • AI
    The **W5VS-AB1-R2** is a high-precision, space-saving signal conditioner (transducer) manufactured by **M-System**. It is specifically designed to convert an AC voltage input into a standard DC output signal that is proportional to the Root Mean Square (RMS) value of the input. --- ### ## Technical Specifications Below are the primary electronic characteristics of the W5VS-AB1-R2: | Parameter | Specification | | :--- | :--- | | **Input Signal** | 0 – 110V AC (Standard range for 'A' code) | | **Output Signal** | 4 – 20mA DC (Standard range for 'B1' code) | | **Power Input** | 24V DC (Code 'R2') | | **Accuracy** | ±0.3% | | **Response Time** | ≤ 0.5 seconds (0 – 90%) | | **Isolation** | Input to output to power (2000V AC @ 1 minute) | | **Mounting** | DIN Rail / Surface mount | --- ### ## Key Electronic Components & Features ### 1. RMS Sensing Circuit Unlike average-sensing transducers, the W5VS-AB1-R2 uses **RMS (Root Mean Square)** conversion. This allows the device to accurately measure distorted waveforms, such as those produced by thyristor controls or electronic ballasts, ensuring the DC output remains precise even if the AC input is not a perfect sine wave. ### 2. Triple Isolation The device features a "3-port" isolation architecture: * **Input-to-Output:** Protects the PLC/Controller from high-voltage surges on the AC line. * **Input-to-Power:** Prevents input noise from affecting the power supply rail. * **Output-to-Power:** Eliminates ground loops between the controller and the transducer power source. ### 3. Ultra-Slim Housing (W5 Series) The "W5" designation refers to the ultra-slim profile (7.5 mm width). This is achieved through high-efficiency surface-mount technology (SMT) and low-heat dissipation components, allowing for high-density installation in electrical panels. ### 4. Zero/Span Adjustments The front panel typically includes multi-turn trimmers. * **ZERO:** Adjusts the 4mA baseline. * **SPAN:** Adjusts the 20mA full-scale point. --- ### ## Connection Diagram (Generic) ```text [ AC INPUT ] ----> (Terminals 1 & 2) [ 24V DC PWR ] ---> (Terminals 7 & 8) [ 4-20mA OUT ] <--- (Terminals 5 & 6) ```
    ✨ Follow-up Questions
    • ⤷ What is the difference between RMS sensing and average sensing in this model?
    • ⤷ Can this transducer handle frequencies higher than 60Hz?
    • ⤷ What are the specific wiring terminal assignments for the W5VS series?