WRPP-CAJ-R2
AI

The **WRPP-CAJ-R2** is a specific model of a **flexible Rogowski coil** current sensor, typically used for AC current measurement in industrial environments. These sensors are known for their ability to measure high currents without the saturation issues found in traditional iron-core current transformers (CTs).
---
### 1. Key Electronic Specifications
The performance of the WRPP-CAJ-R2 is defined by its electrical characteristics, which allow it to integrate with power meters and monitoring systems.
| Specification | Description |
| :--- | :--- |
| **Sensor Type** | Rogowski Coil (Flexible) |
| **Output Signal** | Low-voltage AC (typically mV/kA) |
| **Current Range** | Often scalable from 100A to 100kA |
| **Frequency Range** | 10 Hz to 1 MHz (application dependent) |
| **Accuracy Class** | Generally Class 0.5 or 1.0 |
| **Insulation Voltage** | Often rated for 1kV to 10kV |
---
### 2. Core Electronic Components
The device consists of several critical electronic sub-sections that enable accurate current sensing:
#### A. The Non-Magnetic Core
Unlike traditional CTs, the R2 model uses an air-core (non-magnetic) winding.
- **Benefit:** It eliminates magnetic saturation, allowing it to measure massive fault currents or high-frequency transients linearly.
- **Construction:** A copper winding is wrapped around a flexible plastic or rubberized form.
#### B. The Shielding Layer
The "R2" designation often implies enhanced protection.
- **EMI Shielding:** The coil is wrapped in a grounded conductive layer to prevent electrical noise from nearby high-voltage lines from interfering with the small millivolt signal.
#### C. Connector and Wiring
- **Signal Lead:** Usually a shielded twisted-pair cable.
- **Integrator Requirement:** Because a Rogowski coil outputs a signal proportional to the *derivative* of the current ($V_{out} = M \cdot di/dt$), the electronic signal must pass through an **Integrator circuit** (either built-in or external) to convert it back into a standard voltage or 4-20mA signal.
---
### 3. Comparison: Rogowski vs. Standard CT
| Feature | WRPP-CAJ-R2 (Rogowski) | Traditional Iron-Core CT |
| :--- | :--- | :--- |
| **Saturation** | None | Possible at high currents |
| **Weight** | Very Light | Heavy |
| **Installation** | Wrap-around (Clip-on) | Must break circuit or use bulky split-core |
| **Linearity** | High across all ranges | Limited to specific range |
---
### 4. Typical Application Circuit
When integrating this part into a system, the electronic flow follows this path:
```mermaid
graph LR
A[Primary Conductor] --> B[WRPP-CAJ-R2 Coil]
B --> C[Integrator/Amplifier]
C --> D[ADC / Power Meter]
```
- ⤷
Does the WRPP-CAJ-R2 require an external power supply for the integrator?
- ⤷ What is the specific sensitivity (mV/kA) for this model?
- ⤷ Can this sensor be used for DC current measurement?