FEATURES
❏ Combination of Ceramic tube and Platinum electrodes is adopted
for high anti-corrosive, anti-erosion, and anti-penetration
capability.
❏ Dimensionally stable measuring tube with excellent temperature
resistance and long-term stability, no creep and no abrasion as is
the case with plastic liners.
❏ Stainless steel housing is adopt.
❏ The newly designed reducing tube offers high accuracy and
stability even for low velocity range and mechanical durability of
measuring tube.
❏ High accuracy of ±0.5% of reading.
❏ High speed data processing for quick response. Suitable for
batch process control and for pulsating fl ow.
❏ The excitation system extendable up to twice the commercial
frequency allows applications to much fl uid noise such as slurry.
❏ Blue dot matrix LCD (with backlight) used for the display. Capable
of providing 1 to 3-digit display.
❏ Equipped with a quick setup function to readily respond to
changed fl ow range, pulse rate, etc.
A touch panel system by an infrared sensor allows you to alter
the settings without removing the cover of the conversion section.
❏ 10kHz high-speed pulse output. Capable of responding to short
batch processes.
❏ Current and pulse output, bi-directional measurement, double
range, status output, control input...Full function provided in
compact design.
|