| Electronic Components Datasheet Search |
|
MB3000ERW Datasheet(PDF) 3 Page - MicroPower Direct, LLC |
|
|
|||||||||||||||||||||||||||||
MB3000ERW Datasheet(HTML) 3 Page - MicroPower Direct, LLC |
|
3 / 4 page ![]() MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com EMC Specifications Parameter Standard Radiated Emissions See Note 1 EN 55022 Class A Conducted Emissions See Note 1 EN 55022 Class A ESD EN 61000-4-2 Criteria B; ±4 kV Contact RS EN 61000-4-3 Criteria A; 10V/m EFT See Note 2 EN 61000-4-4 Criteria B; ±2 kV Surge See Note 3 EN 61000-4-5 Criteria B; ±2 kV CS EN 61000-4-6 Criteria A; 3 Vrms Voltage Dips EN 61000-4-29 Criteria B; 0% - 70% Typical Connection The diagram above illustrates a typical connection of the MB3000ERW series for applications that require meeting EMC standards. The units do not require external components to operate as specified. Some notes on this diagram (starting with the input circuit) are: 1. It is recommended that an external fuse be used.The recommended fuse is shown in the model chart on page 2. 2. An external MOV is recommended on the input to protect the unit in the event of a surge. A recommended value is given in the table at right. 3. An external TVS is recommended on the input to protect the unit in the event of a voltage spike. A recommended value is given in the table at right. 4. The output filtering capacitor (C4) is a high frequency, low resistance electrolytic capacitor. Care must be taken in choosing this capacitor not to exceed the capacitive load specification for the unit. Voltage derating of capacitors should be 80% or above. Notes: 1. All units are rated for EN 55022 (CE/RE) class A without external components. They will meet class B with the addition of the MDCFM-xxW (or a similar discrete filter circuit). Contact the factory for more information. 2. To meet the requirements of EN 61000-4-4 (±2 kV), external components are needed.This can be done discretely, or with the addition of the MDCFM-xxW. Contact the factory for more information. 3. To meet the requirements of EN 61000-4-5 (±2 kV), external components are needed. This can be done discretely, or with the addition of the MDCFM-xxW. Contact the factory for more information. Typical Board Layout: With External Filter/Surge Components 5. Recommended values for components are: Component 24 VIN 48 VIN MOV S14K35 S14K60 L1 56 µH 56 µH TVS SMCJ48A SMCJ90A C1 330 µF/50V 330 µF/100V C2, C3 4.7 µF/50V 2.2 µF/100V L2 1.0 mH 1.0 mH CY1, CY2 1nF/2 kV 1nF/2 kV C0 400 uF/200V 400 uF/200V 6. Input noise and surge suppression modules are available for a number of MPD DC/DC power supplies. A connection for one of these modules is illustrated in the typical board layout shown at Typical Connection: With External Filter ModuleUnit Vin (VDC) Input Capacitor Vout (VDC) Output Capacitor 24 100 µF 3.3 220 µF 5.0 220 µF 48 100 µF 9.0 100 µF 12 100 µF 15 100 µF 24 47 µF the bottom of this page For pricing or full technical information,please contact the factory. 7. In many applications simply adding input/output capaci- tors will enhance the input surge protection and reduce output ripple sufficiently. The input capacitor C1 and output capacitor C4 shown in the typical connection diagram above (& board layout drawing below) illustrate their connection. Rec- ommended capacitor values are given in the table. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |