  AH374-P-B Datasheet HTML 1Page - Diodes Incorporated AH374-P-B Datasheet HTML 2Page - Diodes Incorporated AH374-P-B Datasheet HTML 3Page - Diodes Incorporated AH374-P-B Datasheet HTML 4Page - Diodes Incorporated AH374-P-B Datasheet HTML 5Page - Diodes Incorporated AH374-P-B Datasheet HTML 6Page - Diodes Incorporated AH374-P-B Datasheet HTML 7Page - Diodes Incorporated AH374-P-B Datasheet HTML 8Page - Diodes Incorporated AH374-P-B Datasheet HTML 9Page - Diodes Incorporated Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 12 page
background image
AH374
Document number: DS39163 Rev. 1 - 2
3 of 12
www.diodes.com
December 2016
© Diodes Incorporated
AH374
Absolute Maximum Ratings (Note 5) @TA = +25°C, unless otherwise specified.)
Symbol
Characteristic
Value
Unit
VDD
Supply Voltage (Note 6)
28
V
VOUT (Off)
Output “Off” Voltage
28
V
IO (Sink)
Output
“On” Current (Sink)
25
mA
B
Magnetic Flux Density
Unlimited
PD
Package Power Dissipation
SIP-3 (Ammo Pack),
SIP-3 (Bulk Pack)
550
mW
SC59 and SOT23
230
mW
TS
Storage Temperature Range
-65 to +150
°C
TJ
Maximum Junction Temperature
+150
°C
Notes:
5. Stresses greater than the 'Absolute Maximum Ratings' specified above may cause permanent damage to the device. These are stress ratings only;
functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may be
affected by exposure to absolute maximum rating conditions for extended periods of time.
6. The absolute maximum VDD of 28V is a transient stress rating and is not meant as a functional operating condition. It is not recommended to operate
the device at the absolute maximum rated conditions for any period of time.
Recommended Operating Conditions (@TA = +25°C, unless otherwise specified.)
Symbol
Characteristic
Condition
Rating
Unit
VDD
Supply Voltage (Note 7)
Operating
2.2 to 20
V
TA
Operating Temperature Range
Operating
-40 to +125
°C
Note:
7. The output of IC will be switched after the supply voltage is over 2.2V, but the magnetic characteristics will not be normal until the supply is over 2.5V.
Electrical Characteristics (@TA = +25°C, VDD = 12V, unless otherwise specified.)
Symbol
Characteristic
Condition
Min
Typ
Max
Unit
VOUT
Output On Voltage
IOUT = 20mA
—
300
400
mV
IDD
Supply Current
B < BRP
—
2
4
mA
IOFF
Output Leakage Current
Output off
—
< 0.1
10
µA



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com