| Electronic Components Datasheet Search |
|
MP024-10 Datasheet(PDF) 16 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP024-10 Datasheet(HTML) 16 Page - Monolithic Power Systems |
|
16 / 25 page ![]() MP024-10 – PRIMARY-SIDE CC/CV REGULATOR MP024-10 Rev.1.0 www.MonolithicPower.com 16 4/17/2017 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2017 MPS. All Rights Reserved. Constant Voltage (CV) Operation In constant voltage (CV) mode, the MP024-10 detects the output voltage from FB and generates the switching frequency to regulate the output voltage. To regulate the output voltage on the primary side, FB uses a resistor divider to sample the auxiliary winding voltage (Vaux). The relationship between Vaux and the output voltage (Vo) can be calculated with Equation (5): aux aux O D s N V (V V ) N (5) Where VD is the forward drop voltage of the secondary diode. During the conduction time of the secondary diode, the difference between the output voltage and the voltage on the secondary winding is not constant, since VD varies with the current flowing through the diode. To compensate for the voltage drop difference, the sampling time decreases gradually from tFBS-Max to tFBS-Min as the current limitation folds back from VLimit-Max to VLimit-Min (see Figure 5). 0V tFBS-max for VLimit-Max tons Sampling Point Sampling Point tFBS-min for VLimit-Min Figure 5: Auxiliary Winding Voltage The FB sampling time is able to be customized with different resistor values connected to SS (see Figure 6). See the Electrical Characteristics table on page 5 for all available choices for the sampling time. The entire customization process is completed before start-up and stored in a register, so it does not have any influence on the normal operation. SS RSS Figure 6: External Resistor for Sampling Time Customization The sampling should be chosen almost at the end of the secondary diode conduction period for accurate CV regulation. Constant Current (CC) Operation Figure 7 shows the secondary current waveforms. 0 Is Iout tons T Figure 7: Secondary Current Waveform In constant current (CC) operation, Ipk is fixed, and the CC loop control function maintains a fixed ratio between the secondary diode on time (tons) and the switching cycle. The fixed ratio limits the maximum duty of the secondary side diode on time as shown in Equation (6): ons S Max t D T (6) The relationship between the output constant- current and the secondary peak current (Ipks) is shown in Equation (7): ons out pks pks S Max ons offs t 11 I I I D 2 t t 2 (7) When the secondary diode is turned on, the peak current on the secondary side can be calculated with Equation (8): p pks PK S N II N (8) The output current regulation is shown in Equation (9): p out PK S Max S N 1 I I D 2N (9) For different applications with different kinds of output voltages, DS-Max can be customized from CP. If CP is connected with a capacitor directly or shorted to GND, DS-Max remains at a default value of 0.4. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |