| Electronic Components Datasheet Search |
|
S29PL032J Datasheet(PDF) 73 Page - SPANSION |
|
|
|||||||||||||||||||||||||||||
S29PL032J Datasheet(HTML) 73 Page - SPANSION |
|
73 / 106 page ![]() April 7, 2005 31107A62 S29PL127J/S29PL129J/S29PL064J/S29PL032J 71 PRE L I M INARY Command Definitions Tables Legend: BA = Address of bank switching to autoselect mode, bypass mode, or erase operation. Determined by PL127J: Amax:A20, PL064J and PL129J: Amax:A19, PL032J: Amax:A18. PA = Program Address (Amax:A0). Addresses latch on falling edge of WE# or CE# (CE1#/CE2# for PL129J) pulse, whichever happens later. PD = Program Data (DQ15:DQ0) written to location PA. Data latches on rising edge of WE# or CE# (CE1#/CE2# for PL129J) pulse, whichever happens first. RA = Read Address (Amax:A0). RD = Read Data (DQ15:DQ0) from location RA. SA = Sector Address (Amax:A12) for verifying (in autoselect mode) or erasing. WD = Write Data. See “Configuration Register” definition for specific write data. Data latched on rising edge of WE#. X = Don’t care Notes: 1. See Table 1 for description of bus operations. 2. All values are in hexadecimal. 3. Shaded cells in table denote read cycles. All other cycles are write operations. 4. During unlock and command cycles, when lower address bits are 555 or 2AAh as shown in table, address bits higher than A11 (except where BA is required) and data bits higher than DQ7 are don’t cares. 5. No unlock or command cycles required when bank is reading array data. 6. The Reset command is required to return to reading array (or to erase-suspend-read mode if previously in Erase Suspend) when bank is in autoselect mode, or if DQ5 goes high (while bank is providing status information). 7. Fourth cycle of autoselect command sequence is a read cycle. System must provide bank address to obtain manufacturer ID or device ID information. See "Autoselect Command Sequence" section section for more information. 8. The data is DQ6=1 for factory and customer locked and DQ7=1 for factory locked. 9. The data is 00h for an unprotected sector group and 01h for a protected sector group. 10. Device ID must be read across cycles 4, 5, and 6. PL127J (X0Eh = 2220h, X0Fh = 2200h), PL129J (X0Eh = 2221h, X0Fh = 2200h),PL064J (X0Eh = 2202h, X0Fh = 2201h), PL032J (X0Eh = 220Ah, X0Fh = 2201h). Table 21. Memory Array Command Definitions Command (Notes) Bus Cycles (Notes 1–4) Addr Data Addr Data Addr Data Addr Data Addr Data Addr Data Read (Note 5)1 RA RD Reset (Note 6) 1 XXX F0 Autoselect (Note 7) Manufacturer ID 4 555 AA 2AA 55 (BA) 555 90 (BA) X00 01 Device ID (Note 10)6 555 AA 2AA 55 (BA) 555 90 (BA) X01 227E (BA) X0E (Note 10) (BA) X0F (Note 10) SecSi Sector Factory Protect (Note 8) 4 555 AA 2AA 55 (BA) 555 90 X03 (Note 8) Sector Group Protect Verify (Note 9) 4 555 AAA 2AA 55 (BA) 555 90 (SA) X02 XX00/ XX01 Program 4 555 AA 2AA 55 555 A0 PA PD Chip Erase 6 555 AA 2AA 55 555 80 555 AA 2AA 55 555 10 Sector Erase 6 555 AA 2AA 55 555 80 555 AA 2AA 55 SA 30 Program/Erase Suspend (Note 11)1 BA B0 Program/Erase Resume (Note 12)1 BA 30 CFI Query (Note 13)1 55 98 Accelerated Program (Note 15)2 XX A0 PA PD Unlock Bypass Entry (Note 15) 3 555 AA 2AA 55 555 20 Unlock Bypass Program (Note 15)2 XX A0 PA PD Unlock Bypass Erase (Note 15) 2 XX 80 XX 10 Unlock Bypass CFI (Notes 13, 15)1 XX 98 Unlock Bypass Reset (Note 15) 2 XXX 90 XXX 00 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |